0 maintenance, 1 maintenance schedule – Seed Hawk AIRCART 2015 User Manual
Page 44
SEED HAWK
®
2015 AIRCART OPERATOR’S MANUAL 39
Item
Frequency
(hours)
Service
Notes
Wheel Hubs & Main
Frame
100
100 hrs or annually re-pack
bearings or two pumps grease
Metering System
Shaft
25
100 hrs or start and end of
season. Grease ports and
motor/shaft connection.
Metering
Components
100
100 hrs or before seeding, or
between product changes
Fan System Intake
10
10 hrs or daily (remove
accumulated debris)
Fan System &
Fan Blades
10
10 hrs or daily (must
be intact and clean)
Fill Auger / Conveyor
System
100
When changing between
products, or when stored for
long periods of time
Tanks & Meters
100
When changing between
products, or when stored for
long periods of time
Fill Auger System
Pillow Block Bearings
10/100
10 hrs or daily, and
100 hrs or annually
Fill Auger System
Universal Joints
10/100
10 hrs or daily, and 100 hr or
annually
Hydraulic Return
Line
100
At end of seeding season, or
when stored for long periods
of time
Check all machine
fasteners
100
At the beginning of every
season.
Wheel hub fasteners
and tire pressure
10
10 hrs or daily (inflate to
proper pressure and ensure
hubs are torqued and fasten-
ers are in good condition)
5.0 Maintenance
5.1 Maintenance Schedule
NOTE: The bearings on each
Stainless Steel meter are
sealed. DO NOT GREASE
THESE BEARINGS.
Check
Clean
Lube