7.5 Meter Calibration
7.5.1 Pre-Calibration Setup
1. Remove the plate on the bottom
of the meter and place the calibration
under the meter as shown.
2. Turn the diverter valve to the
lower air stream position for calibra-
tion (return to proper position after
calibration is complete).
NOTE: Wing down pressure
circuit must be active to op-
erate hydraulic drive motors
and meter gates (if equipped).
NOTE: All meters on aircart
must be individually calibrated.
Calibrations must be done
each time a crop is changed.
Measure and record the weight of the empty calibration bucket.
Calibration Bucket Weight: _________________
7.5.2 Loup III Calibration Procedure
1. Navigate the highlight bar to "Meter
Calibration" from the Menu Settings.
2. Highlight the desired meter to
calibrate.
NOTE: It is important to cal-
ibrate as close to the actual
seeding rpm of the roller as
possible. Refer to Section 8.4
for the Meter RPM Chart,
to get an approximate roller
rpm for the specific roller
and drill width.