beautypg.com

Error codes, 1 descriptions – Hired-Hand Farm Hand Series: Vent Master 24 User Manual

Page 31

background image

Part No. 4801-5124 rev 10-03

Farm Hand Vent Master 24

29

SWX 3 - 5/10 minute timer This switch selects between a 5 and 10 minute system timer. If

the switch is on, the timer is 10 minutes.

SWX 4 - Sensor 3 Active

When this switch is in the off position, Sensor 3 is turned off.
Note: For half house brooding, place Sensor 3 in the non-
brooding end of the house, and disable it with this switch when
brooding. If the switch is ON, sensor 3 is used.

SWX 5 - Split Vent Units.

If SWX 5 is ON, PowerTrak #1 will control the Vents and
PowerTrak #2 will control the Tunnel mode. If SWX 5 is
OFF, PowerTrak #1 and PowerTrak #2 will always work
together to maintain static pressure.

SWX 6 - Pascals/mm H

2

O

If SWX 2 is set for Metric units, and SWX 6 is set to OFF
pressure is displayed in Pascals. If SWX 6 is set to ON, the
pressure is displayed in millimeters of water (mm H

2

O).

SWX 7 – Initialize Defaults This switch is not implemented and must remain in the OFF

position.

SWX 8 - Program ‘A’ or

‘B’

This switch is used to toggle between 2 preset programs. This
could be used to store separate summer/winter programs for
instance.

16. Error

Codes

16.1 Descriptions

If your controller is displaying an “E1”, or “E2”, etc. the controller has recorded an error. The
controller records errors from sensor readings, and tunnel related problems. To diagnose your
controller problem, look up the error on the table (under “Error Codes”) and look across the table
to find the components that have failed. (Items with an “x” have failed according to the
controller.)

Error
Code

Description

Sensor 1

Error

Sensor 2

Error

Sensor 3

Error

Sensor 4

Error

Pressure

Error

E1

Sensor 1 Error

X

E2

Sensor 2 Error

X

E3

Sensor 1 & 2 Error

X

X

E4

Sensor 3 Error

X

E5

Sensor 1 & 3 Error

X

X

E6

Sensor 2 & 3 Error

X

X

E7

Sensor 1,2 & 3 Error

X

X

X

E8

Sensor 4 Error

X

E9

Sensor 1 & 4 Error

X

X

E10

Sensor 2 & 4 Error

X

X

E11

Sensor 1,2 & 4 Error

X

X

X

E12

Sensor 3 & 4 Error

X

X

E13

Sensor 1,3 & 4 Error

X

X

X

E14

Sensor 2,3 & 4 Error

X

X

X

E15

All Sensor Error

X

X

X

X

E32

Static Pressure Cycle Error

X

E64

High Static Pressure Error

X

E128

Low Static Pressure Error

X