9.8 Sensor

Calibration

The Vent Master 24 has four sensors that may be calibrated. The parameter(s) for calibration
are PSx with x being the sensor number. The sensor temperature reading is alternately
displayed along with the parameter number. You should never attempt to calibrate a sensor
more than 8 degrees. If you have a setting that far out of range, it indicates that there is a
problem that should be corrected.

PS1 -- Calibrate Sensor 1

This reading can be changed by pressing the + or - button until the desired
reading is displayed.

PS2 -- Calibrate Sensor 2

This reading can be changed by pressing the + or - button until the desired
reading is displayed.

PS3 -- Calibrate Sensor 3

This reading can be changed by pressing the + or - button until the desired
reading is displayed.

PS4 -- Calibrate Sensor 4

This reading can be changed by pressing the + or - button until the desired
reading is displayed.