Features – Hired-Hand System 1000 Power Vent User Manual
Page 8
![background image](/manuals/362849/8/background.png)
System 1000 Power Vent
System 1000 Power Vent
Features
Features
••
5
5
Features
Features
Every grower has different needs; thus the Controller has many
features that can be omitted or included at will to align the system to
your individual needs. This section will cover the various features,
including a brief description, and in most cases give an example to show
the flexibility and ease of setup of this controller.
Ramping
Temperature Ramping
Ramping is a special feature that allows for gradual temperature
reduction during a growout. This feature reduces temperature daily (at
midnight) to provide a slow gradual temperature decrease within the
confinement building. When starting a growout, use the Target Temp
arrows to select your starting temperature. The controller will prompt
you for the following information when ramping is selected: "Number
of days" and "Ending temperature"
If at any time during the period when ramping is active, you feel
that the Temperature is too high, or too low, simply use the target
temperature up or down arrows to adjust the current Target Temp. The
controller will automatically re-calculate the proper temperature
reduction per day needed to reach the ending temperature on the day
selected.
Pressure Ramping
This is probably the most dynamic feature of the unit. It allows you to set a
band of pressure to be maintained, taking into account OUTSIDE temperature.