Manually set speed, Viewing records – Hired-Hand System 1000 Power Vent User Manual
Page 13

System 1000 Power Vent
System 1000 Power Vent
Features
Features
••
10
10
using the Change Setting arrow keys. Repeat for each of the four sensors
as needed.
Manually Set Speed
This option allows you to experiment with the variable speed fans. If
you are not sure of the speed you want, you can test here until you find
the right setting. The controller will ask for a percentage, then when
entered, will run the fan, or fans at that percentage and ask if you would
like to change again. This feature is only operable when in selected
features. The controller will not automatically control temperature, or
vent machines while in selected features.
Viewing Records
The System maintains records on the following items:
Each of the 4 Sensors
Each of the 8 Stages
How long the Controller
has been keeping records
1.Total Runtime
How far below the Target
Temp the temperature
dropped (low)
How far above the Target
Temp the temperature
rose (high)
Average + or - difference
from Target Temp
To View Records, push the Select Feature up arrow key until View
Records is displayed. Use the Change Setting up arrow key to select yes.
Use the Select Feature up arrow key to see the display Sensor 1, number
of hours, amount of low and amount of high. To view the remaining
sensors, use the Select Feature up arrow key. After the sensors have all
been displayed, the Select Feature will display Sensor 1 Average - or +
from target and the total amount of hours it has been recording. To
view the remaining sensors, use the Select Feature up arrow key. After
the sensors have all been displayed again, the Select Feature will display
Stage 1 Runtime. To view the remaining stages, use the Select Feature
up arrow key. Push Select Feature again. It will display Reset Records.
Use the Change Setting up arrow key to choose whether you wish to
clear the records and start over (yes) or (no).
Example of Sensor 1 Display:
Sensor 1 14.37 hours
Low 4.0 F. High 1.0 F.