beautypg.com

Checking for zoning problems – Brocade Fabric OS Troubleshooting and Diagnostics Guide (Supporting Fabric OS v7.3.0) User Manual

Page 95

background image

Fabric OS Troubleshooting and Diagnostics Guide

79

53-1003141-01

Zone conflicts

9

Round-trip min/avg/max = 1012/1136/1442 usec

Pinging 21:00:00:20:37:25:ad:05 [0x211e8] with 12 bytes of data:

Request rejected

Request rejected

Request rejected

Request rejected

Request rejected

5 frames sent, 0 frames received, 5 frames rejected, 0 frames timeout

Round-trip min/avg/max = 0/0/0 usec

switch:admin>

The following example is sample output from the fcPing command in which one device accepts the
request and another device does not respond to the request:

switch:admin> fcping 0x020800 22:00:00:04:cf:75:63:85

Source:

0x20800

Destination: 22:00:00:04:cf:75:63:85

Zone Check: Zoned

Pinging 0x020800 with 12 bytes of data:

received reply from 0x020800: 12 bytes time:1159 usec

received reply from 0x020800: 12 bytes time:1006 usec

received reply from 0x020800: 12 bytes time:1008 usec

received reply from 0x020800: 12 bytes time:1038 usec

received reply from 0x020800: 12 bytes time:1010 usec

5 frames sent, 5 frames received, 0 frames rejected, 0 frames timeout

Round-trip min/avg/max = 1006/1044/1159 usec

Pinging 22:00:00:04:cf:75:63:85 [0x217d9] with 12 bytes of data:

Request timed out

Request timed out

Request timed out

Request timed out

Request timed out

5 frames sent, 0 frames received, 0 frames rejected, 5 frames timeout

Round-trip min/avg/max = 0/0/0 usec

switch:admin>

Checking for zoning problems

1. Enter the cfgActvShow command to determine if zoning is enabled.

If zoning is enabled, it is possible that the problem is being caused by zoning enforcement
(for example, two devices in different zones cannot detect each other).

If zoning is disabled, check the default zone mode by entering the defZone

--

show

command. If it is no access, change it to all access. To modify default zone mode from no
access to all access, enter the defZone

--

all command, and then the cfgSave command.

2. Confirm that the specific edge devices that must communicate with each other are in the same

zone.

If they are not in the same zone and zoning is enabled, proceed to

step 3

.