Performance issues – Brocade Fabric OS Troubleshooting and Diagnostics Guide (Supporting Fabric OS v7.3.0) User Manual

Page 38

background image

22

Fabric OS Troubleshooting and Diagnostics Guide

53-1003141-01

FC-FC routing connectivity

2

Target port is Embedded

Hop In Port Domain ID (Name) Out Port BW Cost

-----------------------------------------------------------------------------

0 2 1 (sw0) 6 4G 500

1 23 2 (sw0) 8 4G 500

2 4 3 (sw0) 3 4G 500

3 2 4 (sw0) 24 4G 10000

4 3 7 (switch_3) 2 4G 500

5 27 5 (switch_3) 24 - -

Reverse path

6 24 5 (switch_3) 27 4G 500

7 2 7 (switch_3) 3 4G 500

8 24 4 (sw0) 2 4G 500

9 3 3 (sw0) 4 4G 10000

10 8 2 (sw0) 23 4G 500

11

6

1 (sw0)

2

-

-

(output truncated)

For details about the pathInfo command, refer to the Fabric OS Command Reference.

Performance issues

Symptom

General slow-down in FCR performance and scalability.

Probable cause and recommended action

As LSAN zone databases get bigger, it takes more switch resources to process them. Use the
enforce tag feature to prevent a backbone switch from accepting unwanted LSAN zone databases
into its local database.

Symptom

Host application times out.

Probable cause and recommended action

The FCR tends to take a long time (more than 5 seconds) to present and set up paths for the proxy
devices. Certain hosts are able to do discovery much faster and, as a result, they end up timing out.
Use the speed tag feature to always present the target proxy to the host. This helps sensitive hosts
to do a quick discovery without timing out or causing an application failure.