beautypg.com

Yokogawa Standalone MW100 User Manual

Page 108

background image

-

108/131 -

IM MW100-S16E-1
Ed01


- Setting to output summary


FL p1, p2, p3, p4 (in case p1 is 1)


p1 : Output type (1)

1 : Output summary

p2 : Data kind (MODBUS_MC, MODBUS_MS,

MODBUS_CC,

MODBUS_CS,

DNP3_MC, DNP3_MS,

DNP3_CC, DNP3_CS

)

MODBUS_MC : Modbus master command status

MODBUS_MS : Modbus master connection status

MODBUS_CC : Modbus client command status

MODBUS_CS : Modbus client connection status

BALANCE :

Results of initial balancing of strain inputs

DNP3_MC :

DNP master command status

DNP3_MS :

DNP master connection status

DNP3_CC :

DNP client command status

DNP3_CS :

DNP client connection status

p3 : First data number (refer Table 45)

p4 : Last data number (refer Table 45)



Table 45. Data kind and data number

Data kind

(p2)

Data number

(p3, p4)

MODBUS_MC

1 to 100

MODBUS_MS

1 to 247

MODBUS_CC

1 to 100

MODBUS_CS

1 to 10

BALANCE

1 to 60

DNP3_MC

1 to 100

DNP3_MS

1 to 10

DNP3_CC

1 to 100

DNP3_CS

1 to 10