8 viewing report files, 8 viewing report files -31, Index – Yokogawa Value Series FX1000 User Manual
Page 40
2-31
IM 04L21B01-63EN
Displaying Data
1
2
3
Index
2.8 Viewing Report Files
This section explains how to view report files.
Click the [Open] icon on the toolbar, or select [File] - [Open] on the menu bar. In the [Open]
dialog box, select a report file. The report file name extension is .DAR.
Displaying Report Data Values
The following figure is an example in which hourly report and daily report are stored in a
single report file.
Status
The following characters are displayed in Status.
Character String Meaning
Er
A measurement or computation error occurred during the period over which
the report was created.
Note: “Er” is displayed for the following types of channels:
Channels that are set to Log scale (the report computation result will
be an error).
Math channels whose reference channels are set to Log scale (the
computation result will be an error).
Ov
An over range or computation overflow occurred during the period over which
the report was created.
Pw
A power failure occurred during the period over which the report was created.
Cg
The time was changed during the period over which the report was created.
Bo
The burn out occurred during the period for the report.