Yokogawa Button Operated MV2000 User Manual
Page 56
4-4
IM 04L47B01-01EN
State wth waveform dsplay of dsplay group data
Vew menu tems
State wth waveform dsplay
Display
One waveform window is displayed, and the selected groups are
displayed by groups.
Display entire file
The files including the selected groups are displayed. Waveform windows
are displayed for the number of files including groups. Groups in the
same file are displayed in the same window.
Additional display in
the active window
All tags in the groups added to the display groups are added. Because
tags are added, messages added to the relevant groups are set to No
Display by default. The group name is destroyed. When the max. number
of tags which can be displayed is exceeded, a message that some tags
cannot be added is displayed.
State wth waveform dsplay of message data
Vew menu tems
State wth waveform dsplay
Display
One waveform window is displayed, and the groups with the selected
messages are displayed by groups.
Display entire file
Files including groups with the selected messages are displayed.
Waveform windows are displayed for the number of files including groups
with messages. Messages in the same file are displayed in the same
window.
Additional display in
the active window
Groups with messages are added. When the max. number of groups is
exceeded, a message that some groups cannot be added is displayed.
State wth waveform dsplay of fle data
Vew menu tems
State wth waveform dsplay
Display
One waveform window is displayed and the files are displayed by groups
according to the file groups.
Display entire file
Waveform windows are displayed for the number of selected files.
However, display is made in the same window when the Start/Stop time
(continuous file) is the same.
Additional display in
the active window
All groups in the file are displayed additionally as groups. When the max.
number of groups is exceeded, a message that some groups cannot be
added is displayed.
Waveform display
Display of the most recent data waveforms
Export
Copying in the format created by the device is performed from under
management to the specified folder.
To Excel[File]
Files selected in the list are converted to Excel.
To Text[File]
Files selected in the list are converted to text.
Delete
Moves files to Deleted data. Files whose waveform data is being
displayed cannot be deleted. You can delete an instrument only if all the
files of the instrument have been deleted.
State wth waveform dsplay of contnuous data
Vew menu tems
State wth waveform dsplay
Display
One waveform window is displayed, and the groups of the selected batch
are displayed by groups.
Display entire file
Waveform windows are displayed for the number of selected batches.
Additional display in
the active window
All groups in the batch are displayed additionally as groups. When the
max. number of groups is exceeded, a message that some groups cannot
be added is displayed.
4.1 New Dsplay of Data and Addtonal Dsplay