Yokogawa Button Operated MV2000 User Manual
Page 28
2-4
IM 04L47B01-01EN
Deletng the mport folder settngs
1.
Click the “No.” column of the imported folder.
The folder becomes selected.
2.
Click the
[Delete] button.
The folder registration is deleted.
Immedate automatc mport
1.
Click the icon for
mmedate automatc mport or select Fle > Automatc
mport > Execute mmedately from the menu bar.
Immediate automatic import
Import is performed immediately from the folder specified as the import source.
Explanaton
The following conditions exist for specification of the watch folder.
• Specification of the root directory where DAQManager is installed is not possible.
• The system directory of the OS cannot be specified.
• The management area of DAQManager cannot be specified.
• A hard disk connected via USB or a network folder assigned to a drive can be
specified.
• Specification is possible for a maximum of 8 locations.
A watch folder must be set for automatic import.
Automatic import [Folder specification] monitors the data in the automatically set watch
folder in intervals set by the monitoring time. When the monitoring time is set to “No”,
automatic import is not performed.
When a corresponding file exists in the watch folder, the file is copied (imported) to the
management area. When this occurs, if automatic data conversion was specified, the
converted data is saved to the import folder at the time of import. (The data format can
also be converted after waveform display.) See section 4.9, “Converting Data Formats.”
Even during import, waveform display and other processes can be performed.
When exiting the software, the import is aborted and exit is made.
After import, the navigation window information and the list information are updated to
the most recent information.
The upper limit for devices from which import is possible is 300 units (including deleted
data). Data which have been moved to “Deleted data” of the navigation window and have
been deleted there cannot be imported automatically. See “2.2 Deleting Data Files or
Devices” for “Deleted data.”
2.1 Fle Import and Fle Export