1 installation – Proface FP3900 - 19 Flat Panel" User Manual
Page 40
FP-2500/FP-2600 Series User Manual
3-3
3.1 Installation
• Be sure that the ambient temperature and the ambient humidity are
within their designated ranges. (When installing the FP in a cabinet or
enclosure, the term “ambient temperature” indicates the cabinet or
enclosure’s internal temperature.)
• Be sure that heat from surrounding equipment does not cause the FP
to exceed its standard operating temperature.
• When installing the FP in a slanted panel, the panel face should not
incline more than 30
o
.
• When installing the FP in a slanted panel, and the panel face inclines
more than 30
o
, the ambient temperature must not exceed 40
o
C. You
may need to use forced air cooling (fan, A/C) to ensure the ambient
operating temperature is 40
o
C or below.
Panel
Face
Panel
Interior
NO more than 30 degrees of tilt