2 environmental, 3 structural, 2 environmental -2 – Proface FP3900 - 19 Flat Panel" User Manual
Page 21: 3 structural -2, 1 general specifications
FP-2500/FP-2600 Series User Manual
2.1 General Specifications
2-2
2.1.3
Structural
* 1 The front face of the FP unit, installed in a solid panel, has been tested using condi-
tions equivalent to the standard shown in the specification . Even though the FP unit’s
level of resistance is equivalent to the standard, oils that should have no effect on the
FP can possibly harm the unit. This can occur in areas where either vaporized oils are
present, or where low viscosity cutting oils are allowed to adhere to the unit for long
periods of time. If the FP’s front face protection sheet peels off, these conditions can
lead to the ingress of oil into the FP and separate protection measures are suggested.
Also, if non-approved oils are present, it may cause deformation or corrosion of the
front panel’s plastic cover. Therefore, prior to installing the FP be sure to confirm the
type of conditions that will be present in the FP’s operating environment.
If the installation gasket is used for a long period of time, or if the unit and its gasket
are removed from the panel, the original level of the protection cannot be guaranteed.
To maintain the original protection level, be sure to replace the installation gasket
regularly.
Grounding
External Dimensions
Weight
Cooling Method
Ratings
*1
(For front panel of installed unit)
Natural air circulation
100
Ω
or less, or your country's applicable standard
W317mm [12.48 in] x H243mm [9.57 in] x D58mm [2.28 in]
3.5kg (7.7lb) or less
Equivalent to IP65f (JEM 1030)
2.1.2
Environmental
FP2500-T12
FP2600-T12
FP2500-T42-24V
FP2600-T42-24V
Ambient Operating
Temperature
Storage Temperature
Air Purity (Dust)
Pollution Degree
Corrosive Gasses
Noise Immunity
(via noise emulator)
Noise Voltage: 1,500Vp-p
Pulse Duration: 1ms, 500ns, 50ns
Rise Time: 1ns
Noise Voltage: 1,000Vp-p
Pulse Duration: 1ms, 500ns, 50ns
Rise Time: 1ns
Electrostatic Discharge
Immunity
10Hz to 25Hz 19.6m/s
2
X, Y, Z directions (30min.)
4kV (complies with EN 61000-4-2)
Vibration Resistance
0
o
C to +50
o
C
*1
(the panel face should not incline more than 30
o
C)
-10
o
C to +60
o
C
30%RH to 90%RH
(Non condensing, wet bulb temperature: 39
o
C or less)
Free of dust
Pollution Degree 2
Free of corrosive gasses
Ambient Humidity
* 1 When using a FP-2600 Series unit in an environment where the temperature reaches or
exceeds 40
o
C for an extended period of time, the screen contrast level may decrease
from its original level.