Ladder Monitor Restrictions
•
Depending on the version, your programming tool may not be able to display ladder
programs. For the versions supporting programming tools, see the Pro-face support site
“Otasuke Pro!”. For the instructions that you can monitor, see the manual of the external
device.
•
To use this feature, your CF Card must have 256 MB or more of free space.
•
When reading the ladder program, you cannot read only the comment file.
•
The maximum amount of lines displayed for one ladder program is 25. The 26th line and
after are not displayed. If you specify a device located in the 26th line or after when
searching for a device, the start of the circuit where the device is located will be displayed
but the specified device itself will not be displayed.
•
The power flow is shown by the contact/coil in bold, but the lines connecting contacts to
contacts do not change.
•
The time taken for a screen capture depends on the image quality and screen size. The file
size for a screen quality of 80 will be approximately 200 KB and the capture will take
about 5 to 6 seconds.
•
If you continuously touch the capture (snapshot) button, the screens may not be captured
properly. Allow some time between captures (snapshots).
•
Ladder program and comment password settings are not supported. When a [Stop Read/
Write] password is used, reads will cause a communication error.
•
Please use CF Cards manufactured by Pro-face (Digital Electronics Corporation). If using
another company’s CF Card, damage may occur to the CF Card data.
•
Only English and Japanese can be used for the font.
•
Even when the ladder program has been task reading protected, if the task reading
protection password in PLC has not been set, reading is possible.
•
I/O comments cannot be read from the PLC.
•
Instance names of function blocks, function block names that are called, and parameter
names will not be displayed.
•
The content of function blocks will not be displayed.
•
Floating decimal points of monitor values cannot be displayed.
•
Other program files besides ladder cannot be read or displayed.
- AGP3400 - 7.5 DIO HMI" AGP3300 - 5.7 DIO HMI" AGP3600 - 12.1 FLEX Network HMIs" AGP3500 - 10.4 FLEX Network HMI" AGP3400 - 7.5 FLEX Network HMI" AGP3600 - 12.1 CANopen HMI" AGP3500 - 10.4 CANopen HMI" AGP3400 - 7.5 CANOpen HMI" AGP3300 - 5.7 CANopen HMI" AGP3300H - 5.7 Handheld HMIs" AGP3750 - 15 Multi-Media HMI" AGP3650 - 12.1 Multi-Media HMIs" AGP3550 - 10.4 Multi-Media HMIs" AGP3450 - 7.5 Multi-Media HMI" AGP3360 - 5.7 Multi-Media HMI" AST3300 - 5.7 Basic HMI" AST3200 - 3.8 Basic HMI" AGP3600 - 12.1 Standard HMIs" AGP3500 - 10.4 Standard HMIs" AGP3400 - 7.5 Standard HMI" AGP3300 - 5.7 Standard HMI" AGP3200 - 3.8 Standard HMI"