1 fan 1 configuration, Bios menu 13: fan 1 configuration – IEI Integration PICOe-B650 User Manual
Page 84

PICOe-B650 Half-size PCIe CPU Card
Page 72
o
VCC3V
o
Vcore
o
Vcc
o
+1.05V
o
VDDR
o
VSB3V
o
VBAT
o
5VSB
5.3.8.1 FAN 1 Configuration
Use the FAN 1 Configuration submenu (BIOS Menu 13) to configure fan 1 temperature
and speed settings.
Aptio Setup Utility – Copyright (C) 2011 American Megatrends, Inc.
Advanced
PC Health Status
CPU Smart Fan control
[Auto by RPM]
Target Temp Sensor
[CPU Temperature]
Temperature Bound 1
60
Temperature Bound 2
50
Temperature Bound 3
40
Temperature Bound 4
30
Segment 1 Speed (%)
100
Segment 2 Speed (%)
85
Segment 3 Speed (%)
70
Segment 4 Speed (%)
60
Segment 5 Speed (%)
50
Full Speed Count
3000
---------------------
ÅÆ: Select Screen
↑ ↓: Select Item
Enter
Select
+ - Change Opt.
F1 General
Help
F2 Previous
Values
F3 Optimized
Defaults
F4
Save & Exit
ESC Exit
Version 2.11.1210. Copyright (C) 2011 American Megatrends, Inc.
BIOS Menu 13: FAN 1 Configuration
Î CPU Smart Fan control [Auto by RPM]
Use the CPU Smart Fan control option to configure the CPU Smart Fan.
Î
Auto by RPM
D
EFAULT
The fan adjusts its speed using Auto by RPM
settings