Tabletop or desktop placement, Rack mounting, Tabletop or desktop placement rack mounting – Extron Electronics VSC 500_700_700D User Guide User Manual
Page 43: Mounting the vsc
Mounting the VSC
Select tabletop placement or rack mounting. Follow the appropriate installation instructions
on the following pages.
Tabletop or Desktop Placement
For tabletop or desktop placement only, install the self-adhesive rubber feet/pads (provided)
onto the four corners of the bottom of the enclosure.
Rack Mounting
Underwriters Laboratories Guidelines for Rack Mounting
The following Underwriters Laboratories (UL) guidelines are relevant to the safe
installation of these products in a rack:
Elevated operating ambient temperature — If the unit is installed in a closed or
multi-unit rack assembly, the operating ambient temperature of the rack environment
may be greater than room ambient temperature. Therefore, install the equipment in an
environment compatible with the maximum ambient temperature (Tma: +122 °F, +50 °C)
specified by Extron.
Reduced air flow — Install the equipment in the rack so that the equipment gets
adequate air flow for safe operation.
Mechanical loading — Mount the equipment in the rack so that uneven mechanical
loading does not create a hazardous condition.
Circuit overloading — Connect the equipment to the supply circuit and consider the
effect that circuit overloading might have on overcurrent protection and supply wiring.
Give appropriate consideration to the equipment nameplate ratings when addressing
this concern.
Reliable earthing (grounding) — Maintain reliable grounding of rack-mounted
equipment. Pay particular attention to supply connections other than direct connections
to the branch circuit (such as the use of power strips).
VSC 500/700/700D User Guide • Reference Information
37