beautypg.com

Error responses, Using the command and response tables – Extron Electronics VSC 500_700_700D User Guide User Manual

Page 29

background image

Error Responses

When the VSC receives a valid SIS command, it executes the command and sends a response
to the host device. If the video scan converter is unable to execute the command because
the command is invalid or it contains invalid parameters, it returns an error response to the
host.
The error response codes and their descriptions are as follows:

E01 – Invalid input channel number (the number is too large)

E09 – Invalid function number (the number is too large)

E10 – Invalid command

E13 – Invalid value (the number is out of range/too large)

Using the Command and Response Tables

The command and response table lists valid command ASCII codes, the video scan
converter’s responses to the host, and a description of the command’s function or the results
of executing the command. Lower case characters are acceptable in the command field
unless otherwise indicated. The following ASCII to HEX conversion table is for use with the
command/response table.

ASCII to Hex Conversion Table

Space

Symbol Definitions

X1)

=

Picture adjustment range
(see the note below)

}

=
=

Carriage return (hex 0D)
Space

X1!
X1$
E

=
=
=

Filter adjustment range (0 - 3)
Adjustment range (0 - 127)
Escape key

X!

=

Horizontal and vertical frequencies
(listed to two decimal places, that
is xx.xx)

]

=

CR/LF (carriage return/line feed)
(hex 0D 0A)

X@

=

On/off status where: 0 = off/
disable, 1 = on/enable

NOTE: The default value for horizontal and vertical size is 0512. The default values

for the horizontal and vertical shift are 2048 and 1024, respectively. The actual
minimum and maximum values will vary and are based on the incoming scan
rate.

VSC 500/700/700D User Guide • Serial Communication

23