Serial

Communication

The VSC 500, 700, and 700D can be remotely controlled via a host computer or other device
(such as a control system) attached to the rear panel RS-232/422 connector. The control
device (host) can use either the Extron Simple Instruction Set (SIS™) commands or the
graphical control program for Windows.
The video scan converter uses a protocol with:

9600 baud

1 stop bit

no parity

no flow control

The rear panel RS-232/422 9-pin D connector has the following pin
assignments:

Pin RS-232 function Description
1

No connection

2

Tx

Transmit data

3

Rx

Receive data

4

Tx 2

Transmit data

5

Gnd

Signal ground

6

No connection

7

No connection

8

Rx 2

Receive data

9

No connection

Pin RS-422 function Description
1

No connection

2

Tx-

Transmit ground

3

Rx-

Receive ground

4

No connection

5

Gnd

Signal ground

6

No connection

7

Rx+

Receive data

8

Tx +

Transmit data

9

No connection

DB9 Pin Locations

Female

5

1

9

6

VSC 500/700/700D User Guide • Serial Communication