Unit Reset Function

To reset the VSC to the factory default settings, apply power to the VSC while pressing the
Menu button.

Power

on

Unit

Reset

MENU

AND

NOTE: Press and hold the Menu button, while
applying power, to reset the VSC to factory
default values.

Figure 23.

Unit reset function

Front Panel Security Lockout (Executive Mode)

To prevent accidental changes to settings, simultaneously press the Next and Size buttons
for two seconds to enable the front panel security lockout (Executive mode) of the VSC.
Executive mode locks all front panel functions except centering (shifting). When executive
mode is active, all functions and adjustments can still be made through RS-232 control. For
details on RS-232 control, see the “

Serial Communication

” section.

To disable Executive mode, simultaneously press the Next and Size buttons again for two
seconds.

X-Mode

Enabled

Extron

VSC 500

2 sec.

2 sec.

31.46KHz

59.94 Hz

NEXT

SIZE

X-Mode

Disabled

NEXT

SIZE

NOTE: Simultaneously press the Next and Size buttons for two
seconds to enable Executive mode and lock the front panel
buttons. Executive mode may be enabled at any time and while in
any menu. Press Next and Size again to disable Executive mode.

Figure 24.

Front Panel Security Lockout

Troubleshooting

The image should appear properly on the screen.

If the image does not appear

1.

Ensure that all devices are plugged in.

2.

Make sure that each device is receiving power.

3.

Check the cabling, wiring, and grounding, and make adjustments as needed.

4.

To test the system setup and output, substitute a video test generator for the computer
input.

5.

Confirm that the input is receiving a signal with a compatible scan rate (horizontal
frequency between 24 kHz and 100 kHz, and a vertical frequency of 50 Hz to 120 Hz).

6.

Call the Extron customer support hotline if needed. Be prepared to discuss the steps
you have taken and the equipment involved.

VSC 500/700/700D User Guide • Installation and Operation