Firmware Upgrade Chip Installation
In some cases the VSC firmware may require replacement with an updated version. There is
one user-replaceable firmware chip: U29 — the main microcon troller. The number is printed
on the circuit board. We recommend that you send the unit in to Extron for service and
updates.
WARNING: Changes to firmware must be performed by authorized service personnel
only.
Follow these steps to replace firmware in the VSC.
1.
Disconnect the AC power cord from the VSC to remove power from the unit.
WARNING: To prevent electric shock, always unplug the VSC video scan converter
from the AC power source before opening the enclosure.
Remove the scan converter from the rack or furniture.
2.
Remove the cover of the VSC (the top half of the enclosure) by removing the screws,
sliding the cover back, then lifting the cover straight up.
B/B-Y
G/Y
R/R-Y
RGB INPUT
BUFFERED
LOOP-THR
OUGH
VID
H
V
S-VIDEO
RS-232
/422
50/60 Hz
100-240V 0.3A
OUTPUTS
INPUTS
Remove (3)
Screws from
Back Panel.
Remove (6)
Jack Screw
Nuts.
Slide cover back
then lift straight up.
Remove (8) Screws
VSC 500 remove cover.eps
VSC 500
IN
SDI
B/B-Y
G/Y
R/R-Y
VID
H
V
H
V
H
G
B
R
G
B
V
OUT
GENLOCK
S-VIDEO
RS-232
/422
50/60 Hz
100-240V 0.3A
OUTPUTS
INPUTS
R
Remove (9)
Screws from
Back Panel
Remove (2)
Jack Screw
Nuts
Remove
BNC Hex Nut
VSC 700 remove cover.eps
Slide cover back
then lift straight up.
Remove (8) Screws
VSC 700D
Figure 31.
Top Cover Removal
VSC 500/700/700D User Guide • Reference Information