beautypg.com

Burner orifice removal / replacement, On/off switch on off – A.O. Smith 12 40GPC T 100 User Manual

Page 47

background image

47

BURNER ORIFICE REMOVAL / REPLACEMENT

g

COOLER

HOTTER

Electronic Control Display

Figure 102.

ON/OFF

SWITCH

ON

OFF

Figure 103.

UNPLUGGED

Important: Use only factory authorized replacement

parts. If you lack the necessary skills to properly

perform the installation, you should not proceed, but

get help from a qualified service technician.
Tools required: 3/4” Open-End Wrench or Crescent

Wrench, Phillips Head Screwdriver, Ratchet with 1/4”

socket or 1/4” Nut Driver, Ratchet with 1/2” socket.

Removing the Inner Door/Manifold/Burner Assembly:
1. Set the gas control valve/thermostat to its lowest

setting by pressing the “COOLER” and “HOTTER”

buttons together at the same time holding for 1

second. Then press the “COOLER” button to the

lowest setting (Figure 102).

2. Turn gas control switch to the “OFF” position

(located right side of the gas control valve/

thermostat) and turn off the gas supply to the unit

(Figure 103).

3. Disconnect the electric connection by unplugging

the transformer from the wall outlet (Figure 103).

4. Remove the manifold cover/outer door from the

unit by depressing on the lower portion and pulling

outward.

5. Unplug all the electrical connections from the

bottom of the gas control valve/thermostat

(Figure 104).

6. Disconnect the electrical flag terminals and

air pressure tubing to the pressure switch

(Figure 105).

7. Using a 3/4” open end wrench or a crescent

wrench remove the manifold tube from the gas

control valve/thermostat (turning counterclockwise

-natural gas). Grasp the manifold tube and push

down slightly to free the manifold tube from the

gas control valve/thermostat (Figure 104).

8. Use a 1/4” nut driver or 1/4” socket & ratchet to

loosen the 2 hex head screws on the inner door

so the inner door/manifold/burner assembly can

be removed (Figure 106).

9. Remove inner door/manifold/burner assembly by

grasping the manifold and pulling straight back.

Care should be taken when inner door and burner

assembly passes through jacket opening that it

does not damage any of the electrical wiring or

the air pressure hose (Figure 107).

IMPORTANT:

WHEN BRUSHING ON AN
APPROVED NONCORROSIVE
LEAK DETECTION SOLUTION,
DO NOT SPLASH SOLUTION
ONTO ELECTRICAL CON-
NECTIONS.

IGNITER/
FLAME
SENSE
CONNECTOR

MANIFOLD TUBE

POWER SUPPLY
TRANSFORMER
CONNECTOR

PRESSURE
SWITCH/FAN,
FV SENSOR
CONNECTOR

DISPLAY, ANODE
ROD CONNECTOR

GAS CONTROL
VALVE/THERMOSTAT

Figure 104.

Figure 105.

PRESSURE
SWITCH

MANIFOLD
TUBE

This manual is related to the following products: