FLAME SENSE/HOT SURFACE IGNITER REMOVAL / REPLACEMENT

Important: Use only factory authorized replacement

parts. If you lack the necessary skills to properly

perform the installation, you should not proceed, but

get help from a qualified service technician.
Tools required: 3/4” Open-End Wrench or Crescent

Wrench, Phillips Head Screwdriver, Ratchet with 1/4”
socket or 1/4” Nut Driver.

Replacing the Flame Sense/Hot Surface Igniter

Assembly:
1. Set the gas control valve/thermostat to its lowest

setting by pressing the “COOLER” and “HOTTER”

buttons together at the same time holding for 1

second. Then press the “COOLER” button to the

lowest setting (Figure 89).

2. Turn gas control switch to the “OFF” position

(located right side of the gas control valve/

thermostat) and turn off the gas supply to the unit

(Figure 90).

3. Disconnect the electric connection by unplugging

the transformer from the wall outlet (Figure 90).

4. Remove the manifold cover/ outer door from the

unit by depressing on the lower portion and

pulling

outward.

5. Remove the inner door/manifold/burner assembly.

See Removing Inner Door/Manifold/Burner

Assembly, (page 41) (Figure 91).

6. Lift the retainer clip straight up from the back of

the manifold component block (using a flat-blade

screwdriver), then remove the manifold component

block from the manifold door (Figure 92).

7. Remove and keep the screw securing the flame

sense/hot surface igniter assembly (Figure 92).

8. Remove and discard the old flame sense/hot

surface igniter assembly.

9. Route the new flame sense/hot surface igniter

connector wire through manifold/burner door

opening as shown in figure 92. Secure the

assembly to the bracket ussing screw removed

earlier.
10. Reposition the manifold component block in the

manifold door opening and secure it with the

retainer

clip.

11. Install inner door/manifold/burner assembly,

(see page 42).

12. Restart the water heater by following the

directions on the “Lighting and Operating

Instructions” label located on the front of the water

heater.

13. Upon verifying proper operation of the water

heater, replace the manifold cover/outer door.

Figure 91

INNER DOOR/

MANIFOLD/BURNER

ASSEMBLY

INST

ALL

REMOVE

SLOT

BURNER’S

TIP END

TAB

Screw

Retainer Clip

Manifold Component

Block

Flame Sense/

Hot Surface

Igniter Assembly

Figure 92

g

COOLER

HOTTER

Electronic Control Display

Figure 89.

ON/OFF

SWITCH

ON

OFF

Figure 90.

UNPLUGGED

This manual is related to the following products: