WATER HEATER OPERATION

The figure below shows the water heater’s sequence of operation when a call for heat is initiated. The gas

control valve/thermostat will attempt to light the burner three times. If the flame sense rod in the burner/

manifold assembly does not detect ignition, the control will enter lockout mode indicated by the electronic

control display’s flashing of the appropriate status code.

SEQUENCE OF OPERATION

Main burner flame is detected by

flame sense rod. Air intake fan

and main burner will continue to

operate until water temperature

inside the tank reaches

temperature set point.

Gas valve/thermostat will do a

relay check (relay clicks will be

heard).

Display will show temperature

set point during call for heat.

System will verify pressure

switch operation and start a

5 second pre-purge, then air

intake fan will turn off.

Ignitor will start a 12 second

warm up period. “IGN” will

show on display.

Gas valve/thermostat will open

for 4 second trial for ignition

and fan will turn on.

Gas valve/thermostat is de-

energized and air intake fan

continues for a post purge time

of approximately 5 seconds.

Water heater returns to standby

mode.

Call for heat indicated by

flashing of display screen

status codes.

Draft Blower is energized.