25. Install the air intake chamber screen, ensuring that

the prongs of the lower portion of the air intake

chamber screen are in place in the holding slots.

Using the 2 screws removed in step 8, secure the

air intake chamber screen (Figure 65).

26. Check the air pressure tubing to the fitting on the

of the air intake chamber box and route tubing

in molded inlaid of the air intake chamber box

(Figure 63).

27. Reinstall the air intake chamber gasket (removed

in step 12) on the back lower portion of the new air

intake chamber box (Figure 66).

28. Install the new air intake chamber box to the

combustion chamber pipe. Using a small amount

of soapy water will help. Do not get any water

or soapy water on any electrical connections

or gas control components (Figure 67). NOTE:

UNDUE PRESSURE OR SUDDEN FORCE

SUCH AS HAMMERING OR BEATING ON

THE AIR CHAMBER BOX WITH ANY OBJECT

INCLUDING YOUR HANDS WILL DAMAGE THE

AIR INTAKE CHAMBER BOX AND RESULT IN

FAILURE TO THE HEATER’S OPERATION.

29. Install the air intake chamber box by rotating

the top of the air intake chamber box from left to

right (only a few inches in both directions) while

pressing on the bottom portion of the air intake

chamber box. When properly installed the air

intake chamber box will be in place against the

water heater’s side aligning with the screw holes

(Figure 67).

30. Secure the air intake chamber box to the water

heater’s side by reusing the 4 screws removed in

step 11 (Figure 67).

31. Plug in the electrical flag terminals into the air

pressure switch (Figure 60).

32. Reinstall the FV sensor removed in step 7, by

depressing the snap lock to open the FV sensor

cover, route wiring through sensor cover, plug the

electrical flag terminals connections to the FV

sensor and slide the FV sensor back inside and

close the cover (Figure 60).

33. Connect the air pressure tubing to the pressure

switch (Figure 60).

34. Attach the 3-wire wiring harness connector to the

gas control valve (Figure 59).

35. Check the air hose tubing connection to the

pressure switch to ensure the tubing has not

loosened up or pulled off (Figure 60).

36. Turn on the electrical and the gas supplies to the

water heater. Plug in the electric connection from

the transformer to the electric outlet (Figure 58).

37. Restart the water heater by following the

directions on the “Lighting and Operating

Instructions” label located on the front of the water

heater.

38. Upon verifying proper operation of the water

heater, replace the manifold cover/outer door.

Figure 66.

AIR INTAKE
CHAMBER BOX

REINSTALL
CHAMBER GASKET

Figure 65.

INSTALL THE AIR INTAKE
CHAMBER SCREEN.

Figure 67.

ROTATE FROM
LEFT TO RIGHT

AND

PUSH INWARD

INSTALL SCREWS