EXTERNAL INSPECTION AND CLEANING

Cleaning the Air Intake Chamber Screen:

• At least twice annually the air intake chamber

screen should be inspected for any dust or

debris that may have accumulated on the

louvers.
NOTE: If the water heater is located in an area

that is subjected to lint, pet hair or dirt, it may be

necessary to check the air intake chamber screen

more frequently.
• Use a vacuum cleaner with a hose attachment

to remove any dust or debris that may have

accumulated on the screen.

Air Intake Chamber

Screen

Figure 24.

Cleaning the Combustion Chamber and Air

Diverter Assembly:

• Follow procedure outlined in “Removing Inner

Door/Manifold/Burner Assembly”, page 41.

• Use a vacuum cleaner/shop vac to remove

all loose debris in the combustion chamber.

Use compressed air to clear any dust or

debris that may have accumulated on the air

diverter

assembly.

• Reassemble following the procedure under

“Installing Inner Door/Manifold/Burner

Assembly”, page 42.

Figure 25.

INNER DOOR/

MANIFOLD/BURNER

ASSEMBLY

AIR DIVERTER

ASSEMBLY