Summit Z3‐16 PCI Express Multi‐Lane Exerciser User Manual
25
Setting Up the Summit Z3‐16 Exerciser using an Ethernet Connection
Teledyne LeCroy
3. Connect the USB port to a USB port on the host machine using a USB cable. Go to
Step 4 below.
4. Turn on the power to the host machine or the PCI Express Test Platform 16x2.5GT/s /
16x5.0GT/s / 16x8.0GT/s.
Note:
At power‐on, the Exerciser initializes itself in approximately five seconds and
performs an exhaustive self‐diagnostic that lasts about forty seconds.
5. Follow the Microsoft
®
Windows
®
on‐screen Plug‐and‐Play instructions for the
automatic installation of the Exerciser as a USB device on your analyzing host
machine. (The required USB drivers are installed on your system during software
installation)
6. Click Finish when you see the message that says “Windows has finished installing
the software that your new hardware requires” and the file has been installed in
your host machine.
7. Do not change from USB to Ethernet, or back, without power cycling the Exerciser.
3.3
Setting Up the Summit Z3-16 Exerciser using an Ethernet
Connection
To connect the Exerciser using USB (see
“Setting Up the Summit Z3‐16 Exerciser using a
.
1. Connect the Exerciser to a 100‐volt to 240‐volt, 50 Hz to 60 Hz, 120 W power outlet
using the provided AC power adapter, or to the DC power connector if using the PCI
Express Test Platform.
2. Plug the Exerciser into either the host machine or the PCI Express Test Platform.
Note:
The AC power adapter is capable of supporting supply voltages between 100 volts
and 240 volts, 50 Hz or 60 Hz, thus supporting all known supply voltages around the
world.
3. Connect the Ethernet cable between the Ethernet port on the side of the Exerciser
and an Ethernet port (hub, switch or wall) in your local network.
4. Turn on the power to the host machine or the PCI Express Test Platform 16x2.5GT/s /
16x5.0GT/s / 16x8.0GT/s.
Note:
At power‐on, the Exerciser initializes itself in approximately five seconds and
performs an exhaustive self‐diagnostic that lasts about forty seconds.
5. After you have installed the PETracer application software, perform the following
procedure to connect to a Summit Z3‐16 Exerciser in a local network.
Select the Setup > All connected devices… menu in the PETracer application to
display the Analyzer Devices dialog (see