Summit Z2-16 Exerciser User Manual

Chapter 4: Traffic Generation

Teledyne LeCroy

43

Link

Parameter

Values

Default

Comment

SkipTimer

number of symbols
Off

1360

Periodic timer that controls sending of SKIP ordered
sets at specific intervals. Timer’s value is measured in
number of symbols.

FTSCount

0 to 255

255

Number of FTS ordered sets required (as sent in TS)