Function group 6 – drive status and reset – KB Electronics KBDA-42 User Manual
Page 37
36
Function
No.
Description
Code
Factory
Setting
6.00*
Software Version
—
—
6.01*
Drive Horsepower
—
—
6.02*
Fault Log 1
—
—
6.03*
Fault Log 2
—
—
6.04*
Fault Log 3
—
—
6.05**
Reset Drive to Factory Setting
1110: 50 Hz Operation
1111: 60 Hz Operation
0000
FUNCTION GROUP 6 – DRIVE STATUS AND RESET
* Read only.
** Functions which can only be changed while the drive is in the Stop Mode.
Function
No.
Description
Range/Code
Factory
Setting
7.00*
Multi-Function Input Terminal 1
(1)
0000: Preset Frequency Operation
(2)
0001: Preset Frequency Operation
(2)
0002: Preset Frequency Operation
(2)
0003: Up Frequency Command (See Function No. 7.14)
(3)
0004: Down Frequency Command
(See Function No. 7.14)
(3)
0005: Accel/Decel 2 (See Function No. 7.16)
0006: Forward/Stop Command
(4)
0007: Reverse/Stop Command
(4)
0008: External Fault (N.O. Contact)
0009: Reset
0010: N.O. Start (2-Wire or 3-Wire Start/Stop)
(4)
0011: N.C. Stop (3-Wire Start/Stop)
(4)
0012: External Fault (N.C. Contact)
0000
7.01*
Multi-Function Input Terminal 2
(1)
0001
7.02*
Multi-Function Input Terminal 3
(1)
0002
7.03*
Multi-Function Input Terminal 4
(1)
0009
7.04*
Multi-Function Input Terminal 5
(1)
0010
7.05*
Multi-Function Input Terminal 6
(1)
0003
7.06*
Multi-Function Input Terminal 7
(1)
0004
7.07
*
Preset Frequency 1 (Hz)
0.00 – 240.0
5.00
7.08
*
Preset Frequency 2 (Hz)
0.00 – 240.0
10.00
7.09
*
Preset Frequency 3 (Hz)
0.00 – 240.0
20.00
7.10
*
Preset Frequency 4 (Hz)
0.00 – 240.0
25.00
7.11
*
Preset Frequency 5 (Hz)
0.00 – 240.0
30.00
7.12
*
Preset Frequency 6 (Hz)
0.00 – 240.0
35.00
7.13
*
Preset Frequency 7 (Hz)
0.00 – 240.0
40.00
7.14
*
Up/Down Frequency Control Mode
0000: Free-Running
(5)
0001: Incremental Change (See Function No. 7.15)
0000
7.15
*
Increment of Up/Down Frequency (Hz)
0.01 – 30.00
1.00
7.16
*
Accel/Decel 2 Time (Seconds)
0.3 – 180.0
1.5
FUNCTION GROUP 7 – MULTI-FUNCTION INPUT TERMINALS
(IODA OPTION BOARD REQUIRED)
Note: (1) Each of the 7 Multi-Function Input Terminals can be programmed for any of the respective function codes (0000 – 0011).
(2) Preset Frequencies 1 – 7 are obtained by selecting a specific combination of 3 Multi-Function Input Terminals. The specific frequencies
are programmed in Functions 7.07 – 7.13. (3) For Up/Down Frequency Commands (codes “0003” and “0004”), Frequency Control
(Function No. 2.00) must be set to Up/Down Using MFITs (code “0005”). (4) For Forward/Reverse Stop Commands (codes “0006” and
“0007”) and N.O. Start / N.C. Stop (codes “0010” and “0011”), Run/Stop-Forward/Reverse Control (Function No. 1.00) must be set to
External Contacts (code “0001”). (5) The rate of change of the “UP” Control for frequency setting, using external contacts, is proportional to
the Accel Time setting (3.03). The rate of change of the “DOWN” Control for frequency setting, using external contacts, is proportional to the
Decel Time Setting (3.04).
*Functions which can only be changed while the drive is in the Stop Mode.