Xy base fixed type: single slider type – IAI America IK Series User Manual
Page 4
XY base fixed type: Single slider type
IK2-S(P)XB
S
DWG. No.
GMM07-053E
2/2
8
7
Model
Hex socket-head
countersunk
Tightening torque
M3 x 6 mm
Installation position of IK2-S(P) SXBA (SXBB)
S
Y-axis stroke
Length from end face of guide rail Y
(front side) to fixed end of bearer
50 mm
81.5
100 mm
106.5
150 mm
131.5
200 mm
156.5
250 mm
181.5
300 mm
206.5
350 mm
231.5
400 mm
256.5
Installation position of IK2-S(P) SXBC (SXBD)
S
Y-axis stroke
Length from end face of guide rail Y
(front side) to fixed end of bearer
50 mm
80.0
100 mm
105.0
150 mm
130.0
200 mm
155.0
250 mm
180.0
300 mm
205.0
350 mm
230.0
400 mm
255.0
(Note)
One side of cable bearer 2 [8] is free. The customer should
install cable bearer 2 when installing a handle, etc.
Y-axis
[8] Cable bearer 2
[7] Guide rail Y
Hex socket-head countersunk (4 pcs)
Hex nut (4 pcs)
Installation position of cable bearer 2 [8]
See the table below.
Y-axis
[7] Guide rail Y
[8] Cable bearer 2
Arrange the wires so that each axis will not contact the cables and
connectors when the axis is moved over its entire stroke.
(Note)
If you want to move the actuator with brake by hand, connect the
controller and supply the power and then set the brake release switch to
the release (RLS) side.
* Refer to “Cable affixing method: GMM07-060” for affixing of cables.
X-axis
Y-axis
Cables from hand, etc.
Frame cover
Connect the motor
cable/encoder
cable connectors.
[8] Cable bearer 2
Guide rail
[5] Cable bearer 1