beautypg.com

Xy base fixed type: single slider type – IAI America IK Series User Manual

Page 4

background image

XY base fixed type: Single slider type

IK2-S(P)XB

†††††S

DWG. No.

GMM07-053E

2/2

8


























7



























































Model

Hex socket-head

countersunk

Tightening torque

M3 x 6 mm

Installation position of IK2-S(P) SXBA (SXBB)

†††††S

Y-axis stroke

Length from end face of guide rail Y

(front side) to fixed end of bearer

50 mm

81.5

100 mm

106.5

150 mm

131.5

200 mm

156.5

250 mm

181.5

300 mm

206.5

350 mm

231.5

400 mm

256.5


Installation position of IK2-S(P) SXBC (SXBD)

†††††S

Y-axis stroke

Length from end face of guide rail Y

(front side) to fixed end of bearer

50 mm

80.0

100 mm

105.0

150 mm

130.0

200 mm

155.0

250 mm

180.0

300 mm

205.0

350 mm

230.0

400 mm

255.0

(Note)

One side of cable bearer 2 [8] is free. The customer should
install cable bearer 2 when installing a handle, etc.

Y-axis

[8] Cable bearer 2

[7] Guide rail Y

Hex socket-head countersunk (4 pcs)
Hex nut (4 pcs)

Installation position of cable bearer 2 [8]

See the table below.

Y-axis

[7] Guide rail Y

[8] Cable bearer 2

Arrange the wires so that each axis will not contact the cables and
connectors when the axis is moved over its entire stroke.

(Note)

If you want to move the actuator with brake by hand, connect the
controller and supply the power and then set the brake release switch to
the release (RLS) side.

* Refer to “Cable affixing method: GMM07-060” for affixing of cables.

X-axis

Y-axis

Cables from hand, etc.

Frame cover

Connect the motor
cable/encoder
cable connectors.

[8] Cable bearer 2

Guide rail

[5] Cable bearer 1