Document configuration settings – Securitron M680BDCX User Manual
Page 5
![background image](/manuals/349140/5/background.png)
PN# 500-10560
Page 5
Rev. D, 07/12
SW2
DIP Switch:
PIR Enable and
Delay Selection
ENABLE PIR
Switch 5 ON
5 second delay
Switch 3 OFF (default)
10 second delay
Switch 3 ON
DIP Switch:
Auto Relock Timer
Enable and Delay
Selection
The Auto Relock Delay
Timer is disabled by
default. The delay can
be enabled by setting
Switch 4 to ON, and
then selecting a time
delay with Switch 1 and
Switch 2.
DISABLE Delay Timer
Switch 4 OFF (default)
ENABLE Delay Timer
Switch 4 ON
5 second delay
Switch1 OFF, Switch2 OFF
10 second delay
Switch1 OFF, Switch2 ON
20 second delay
Switch1 ON, Switch2 OFF
30 second delay
Switch1 ON, Switch2 ON
J1
Terminal Block 1
Tamper Switch
A 2-wire terminal block providing a SPDT contact that
changes state as determined by JP1 when the cover is
sensed to be removed by SW1.
J5
Terminal Block 5
Input Power
A 3-wire terminal block providing connection to the power
supply. Position 1 is a constant (+) for camera and PIR.
Position 2 is (+) for the lock power, position 3 is (-).
J6
Terminal Block 6
BondSTAT
A 3-wire terminal block providing a SPDT 1-Form C
contact that changes state when the BondSTAT bond is
interrupted.
J8
Terminal Block 8
Door Position Switch
A 6 wire terminal block providing:
(1-2) SPST contact determined by Jumper 3 based on
door position switch.
(3-4) SPST contact state change is determined by Jumper
2 based on REX activation.
(5-6) 2 position dry contact, closure disables PIR.
BNC Cable
BNC Connector for
Camera Signal
The included BNC cable can be routed through either side
of the maglock housing for connection to surveillance
system
3.
Document Configuration Settings
The Board Settings are now complete. Copy your settings onto the adhesive-backed Circuit Board Settings label
enclosed with the mounting hardware packet.
M670/M680 Settings
Jumper 4 (JP4) LED Enable
ENABLED DISABLED
Jumper 5 (JP5) LED SECURE Color
RED
GREEN
*Jumper 1 (JP1)Tamper Select Mode NC 1-2
NO 2-3
*Jumper 2 (JP2) Request to Exit Mode NO 1-2
NC 2-3
*Jumper 3 (JP3) Door Position Mode NC 1-2
NO 2-3
*(SW2) Auto Relock Delay
ENABLED DISABLED
*Delay (in seconds)
0 5 10 20 30
*available on select models
1-800-MAGLOCK
Important! Complete the label and affix
to the inside cover of your Magnalock
®
This information will be needed if the lock
needs to be serviced, replaced or inspected.