INSTALLATION INSTRUCTIONS FOR SMLS/SMSS
Surface Mount Lock Shear & Surface Mount Strike Shear
1. RECOMMENDED TOOLS
Drill Motor
Drill Bit: 3/8” [9.5mm]
Screwdrivers: Phillips and Standard
Measuring Tool (ruler or tape measure)
Hex (Allen) Wrenches: 1/8” (provided in Metric Hardware Pack), 5/32” [4mm] and 3/16”
Blind Nut Installation Tool
2. INSTALLATION INSTRUCTIONS
Magnalock Installation using SMLS/SMLSM
Figure 1 below is an exploded illustration of the general SAM lock mounting configuration
available using the hardware provided:
2
1
4
3
(6) 10-32 UNF X 3/8" LONG
FLAT HEAD SOCKET SCREWS
SUPPLIED WITH SAM LOCK OR
METRIC (SMLSM) VERSION OF
LOCK MOUNT
(REFERENCE) SAM LOCK
- NOT INCLUDED
Figure 1
Note: The items represented by the phantom/dashed lines are for reference only – the SAM
Magnalock and its associated hardware are NOT included with this product.
U.S. Standard:
ITEM QTY
DESCRIPTION
1
1
Lock/Strike Mounting Bracket
2 1
Lock/Strike
Bracket
Cover
3
3
1/4-20 UNC X 1” Long Socket Head Cap Screw
4
3
1/4-20 UNC Blind Nut, 1-Piece, Steel
Metric:
ITEM QTY
DESCRIPTION
1
1
Lock/Strike Mounting Bracket
2 1
Lock/Strike
Bracket
Cover
3
3
M6-1.0 X 25MM Long Button Head Socket Cap Screw
4
3
M6-1.0 Blind Nut, 1-Piece, Steel
5
6
10-32 UNF X 3/8” Long Flat Head Socket Screw
6
1
Hex Wrench, 1/8”