Securitron M680BDCX User Manual
Page 4
PN# 500-10560
Page 4
Rev. D, 07/12
Component Label
Component Name
Selection
Position
JP1
Jumper 1: Tamper
Switch Mode Select
A 3-pin jumper that
controls the output
setting for Tamper
Switch SW1 at
Terminal Block J1.
(NC) Normally Closed
Circuit Closed when Cover
Closed (default setting)
(NO) Normally Open
Circuit Open when Cover
Closed
JP2
Jumper 2: Request
to Exit Mode Select
A 3-pin jumper that
controls the output
setting for the Request
to Exit (REX) signal in
Terminal Block J8
Position 3 & 4.
(NO) Normally Open
Circuit Open, Circuit closes
when REX active (default
setting)
(NC) Normally Closed
Circuit Closed, Circuit opens
when REX active
JP3
Jumper 3:
Door Position
Mode Select
A 3-pin jumper that
controls the output
setting for the Door
Position Switch (DPS)
in Terminal Block J8
Position 1 & 2.
(NC) Normally Closed
Circuit Closed when Door is
Closed (default setting)
(NO) Normally Open
Circuit Open when Door is
Closed
JP4
Jumper 4:
LED Enable
A 2-pin jumper that
enables the LED.
LED ENABLED
(default setting)
LED DISABLED
(jumper removed)
JP5
Jumper 5:
LED Color Select
A 2-pin jumper that
controls the color of the
LED output. Output
options are red or
green.
SECURE = RED LED
(default setting)
SECURE = GREEN LED
(jumper removed)