Securitron MM15 User Manual
Door prep/armature mounting, Mm15 magnalock mounting
1
With the door closed, align the
armature template between the
tabs on the mounting plate and
mark the three holes.
2
For Metal Doors: Locate the middle
marked hole. Center punch and drill
a 3/8” hole through the door. Enlarge
hole from the outside face to 1/2”.
For Wood doors: Drill a 1/2” hole
through the door.
3
Center punch and drill two 1/4”
(x 1/2” deep min.) holes in the
inside face of the door for the
two anti-rotation pins.
4
Lay the armature on a clean,
flat surface and insert the 3/16”
x 3/4” roll pins provided into
the two holes on the back of
the armature. Gently tap the
roll pins with a small hammer
or mallet until they are firmly
seated.
5
Insert sex bolt from the outside
face of the door.
6
Place the O-ring on the shoulder
screw and insert through the
armature.
7
Place the spring washer(s) on
the shoulder screw to provide
the spacing required for the
armature to fully contact the
MM15.
8
Locate the armature with roll
pins onto the door.
Fasten shoulder screw to sex bolt
with a 3/16” hex wrench using
thread lock. Additional spring
washers may be necessary to
ensure that the armature floats
properly, but is not loose.
9
Door Prep/Armature Mounting
1
QTY
COMPONENT
2
Secure the MM15 to the mounting plate with the three 1/4-20 x
1-3/4” cap screws, feeding the wiring through the filler plate and
header. If using conduit option, the wires exit through the side of
the MM15 Maglock.
3
Replace the MM15 cover by aligning it with the tapped holes and
pushing it up until the lip snaps into place.
4
Fasten cover with the two #6-32x1/4” flat head screws.
MM15 Magnalock Mounting
The standard MM15 Maglock unit will operate on 12 to 24 VAC or VDC
and is not polarity sensitive.
18-gauge (minimum) wire should be used to minimize voltage drop.
Connection of a reverse diode or M.O.V. in parallel with the MM15’s
power input is not necessary. The MM15’s internal circuitry suppresses
the inductive kickback often seen with electromagnetic coil locks.
Monitor Switches
MM15 Maglocks ordered with the monitoring option are fitted with
two SPDT microswitches that provide the following indications:
Door Position – Armature closed against the MM15 Maglock.
(*) Tamper Warning – Indicates that the MM15 is being
forced enough to activate the locking arms. When
locking arms are activated, tamper switch changes state.
(1)
MM15 Maglock with Cover
(1)
Mounting Plate
(1)
Armature
(1)
Armature Template
(2)
Roll Pins - 3/16” x 3/4”
(1)
Sex Bolt
(1)
Shoulder Screw
(1)
Rubber O-Ring
(3)
Spring Washers
(4)
Blind Nuts
(4)
Pan Head Screws - 1/4-20x1”
(3)
Socket Head Cap Screws
1/4-20x1-3/4”
(1)
Hex Wrench
(2)
Threadlock
(8)
Wire Nuts
This product must be installed according
to all applicable building and life safety codes.
MAGNACARE LIFETIME REPLACEMENT WARRANTY
For warranty information visit:
www.securitron.com/en/site/securitron/about
MagnaCare-warranty/
SECURITRON MAGNALOCK CORP.
1-800-MAGLOCK
www.securitron.com
Remove the cover from the MM15.
Electrical Installation and Wiring
Component List and Identification
MM15-01 Rev. C