1. SPECIFICATIONS
Physical:
Holding Force: 2,000 Lbs. [907 Kg]
Dimensions:
Inches: 2-3/4”L X 7-1/4”H X 3-1/4”D
Millimeters: 70 L X 184 H X 83 D
Electrical:
12 Volts DC Current Requirement:
Initial (Peak): (~1 sec.) 870 mA
Reduced: 290 mA
Power Consumption: 3.5 Watts
24 Volts DC Current Requirement:
Initial (Peak): (~1 sec.) 720 mA
Reduced: 170 mA
Power Consumption: 4.1 Watts
2. PRODUCT OVERVIEW
Upon unpacking this product, an inventory should be made to ensure that all the required
components and hardware have been included. Along with these instructions and the
installation template, the lock assembly should include the following items:
3. RECOMMENDED TOOLS
Hammer
Screwdriver, #2 Phillips
Center punch
Hex (Allen) wrench, 3/16” or 5mm
(Tap, 1/4-20 UNC-2B or M6-1.0)
Drill bits: 5/16”, 3/8”, 13/16”
4. INSTALLATION INSTRUCTIONS
Pre-Installation Survey
Due to the variety of mounting configurations available with this product, it is strongly
recommended that an initial physical survey and assessment be made of the actual area to
which the lock will be installed. A determination of the optimal method of mounting should be
made prior to installation with considerations made to the following:
A. Physical strength of mounting areas:
It is recommended that the structural integrity of mounting surfaces be strong enough to
meet or exceed the holding force of the lock.