Output signals from the SAN Servo Controllers
The output signals listed below are signals available from the individual
spindle controller (SAN) Unit and only indicate status from that particular
spindle. They do not indicate status from any other spindle or group of
spindles. These are typically used for individual spindle status display.
The number in the tables below are only for reference showing total number of
signals available per spindle. (Total number of available signals from the SAN
Units: 31 Spindles X 28 Signals = 868 signals)
Current Warning High
AMP HI
28
Current Warning Low
AMP LO
27
Torque Rate 3 High Reject
TR3 HI
26
Torque Rate 3 Low Reject
TR3 LO
25
Torque Rate 2 High Reject
TR2 HI
24
Torque Rate 2 Low Reject
TR2 LO
23
Torque Rate 1 High Reject
TR1 HI
22
Torque Rate 1 Low Reject
TR1 LO
21
Angle High Reject
AN HI
20
Angle Low Reject
AN LO
19
Peak Torque High Reject
PT HI
18
Peak Torque Low Reject
PT LO
17
Final Torque High Reject
FT HI
16
Final Torque Low Reject
FT LO
15
Time 2 Reject High
TM2 HI
14
Time 2 Reject Low
TM2 LO
13
Time 1 Reject High
TM1 HI
12
Time 1 Reject Low
TM1 LO
11
Parameter Select 4 bit
P SEL 4
10
Parameter Select 3 bit
P SEL 3
9
Parameter Select 2 bit
P SEL 2
8
Parameter Select 1 bit
P SEL 1
7
Busy
BUSY
6
Ready
RDY
5
In Bypass
BYP
4
Abnormal
ABN
3
Accept
ACC
2
Reject
REJ
1
AFC1500 SAN Servo Controller Output Signals
Chapter 4: I/O & Output Data