The Fulton Companies*FB-S Series Manual*Version 2010-0820 rev. 3/5/13

Page 64

Caution

TOPOG-E gasket have a finite life after installation and must be

renewed annually. It is important that the instructions given in this section

are adhered to.

The boilers are fitted with TOPOG-E gaskets in all the inspection holes of the

boiler. These gaskets work very well and millions have been safely used over the

last 30 years, however, it is absolutely essential to observe a few simple rules in

order to get the best performance from your installation. Elastomeric Vulcanizates,

which form the basis of TOPOG-E gaskets, undergo degradation from many

sources including heat, oxygen, stress, and overdosing from certain types of water

treatment. This takes the form of material oxidation, hardening/embrittlement and

cracking which may result in gasket failure. Steps must be taken to minimize the

effects of such attacks.

Water treatment and oxygen attack can be combated by ensuring that the gasket is

aligned correctly so that only the extreme edges of the gasket are exposed. If a

new gasket leaks after fitting this is almost certainly due to incorrect sealing or

alignment. Incorrect sealing or misalignment will reduce the life of the gasket and

cause problems later.

Under stress can be avoided by tightening just sufficiently to stop any leakage

when fitting cold and before firing the boiler. Fire the boiler and then gradually

warm the boiler up, allowing the increasing steam pressure to take over and

complete the seal. The will allow the gasket material to contract naturally and

follow the topography of the mating surfaces. The securing nut can then broken

when the boiler is cold and under negative pressure.

Gentle warming of the boiler on initial firing after maintenance will also help to

ensure that the rubber ‘cures to shape’. If the rubber post-cures, the elastic

memory will be destroyed and any initial over-tightening will cause the gasket

to become hardened and embrittled, leading to cracks and eventual failure.

Fitting Instructions

Blowdown the boiler completely and examine all inspection holes in the boiler. If

any leakage is evident, proceed as follows:

a) Remove the old gasket and thoroughly clean the mating faces of the cover plate

and boiler ring.