3-12.2 Analog Inputs and Computations

The Analog input signal is filtered electronically
and converted to a 0 - 10000 Hz input frequency.
(See Section 7, K Factor Calculation and Sec-
tion 4-2, Analog Inputs).

Computations:

Pulses In = Count
Count K Factor

Pulses In = Rate
Rate K Factor

Batch Total

=

Count (since last Batch

Reset)

Grand Total

=

Count (since last Grand

Total Reset)

Rate

= Rate

Tau

Tau = 1 sec or WINDOW if (Rate/1 sec) = 0

(See Sections 1-3 and 3-10, Setting the

Ratemeter)

Frequency Out

= Count

(Sequenced out as per OUT FREQ selec-
tion and buffered to 9999 pulses)
(See Sections 1-3 and 3-10, OUT FREQ)

Prewarn Out

=

Count

Preset - Prewarn (if Reset to 0)

Count

Prewarn (if Reset to Preset)

Preset Out

=

Count

Preset (if Reset to Zero)

Count

0 (if Reset to Preset)

3-12 Internal Operation

3-11.1 Digital Inputs and Computations

The 3-30 Volt input signal is filtered electroni-
cally (See Section 4-1, Digital Pulse Inputs).

Computations:

Pulses In = Count
Count K Factor

Pulses In = Rate
Rate K Factor

Batch Total

=

Count (since last

Batch Reset)

Grand Total

=

Count (since last

Grand Total Reset)

Rate

= Rate

Tau

Tau = 1 sec or WINDOW if (Rate / 1 sec) = 0

(See Sections 1-3 and 3-10, Setting the

Ratemeter)

Frequency Out

= Count

(Sequenced out as per OUT FREQ selec-
tion and buffered to 9999 pulses)
(See Sections 1-3 and 3-10, OUT FREQ)

Analog Out

=(

Rate

- SET LOW) x16 + 4

(SET HIGH - SET LOW)

(See Sections 1-3 and 3-10, ALG OUT)

Prewarn Out

=

Count

Preset - Prewarn (if Reset to 0)

Count

Prewarn (if Reset to Preset)

Preset Out

=

Count

Preset (if Reset to Zero)

Count

0 (if Reset to Preset)