Liquid Controls SP2800 User Manual
Page 20
16
3-10 Setup Procedure For The Batcher (continued)
MENU ITEM 4 COUNT (continued)
PRESS
DISPLAY
R0
↓↓↓↓↓
SP
↓↓↓↓↓
Store new K Factor.
RO is Reset to zero. SP is Reset to Preset. This selection determines whether the unit
counts up or counts down. If RO is selected ( B is pressed), the unit will count in the "up"
direction towards the Preset (dropping out the Prewarn, if passed). If SP is selected ( D is
pressed), the unit starts at the Preset and counts "down" towards zero (dropping out the
Prewarn at its set value.)
or
Selects by moving the cursor under the
arrow by R0 or SP
DEC LOC
Store R0 or SP.
DEC LOC allows the user to choose where the decimal point will be located when
the Batch Count or Grand Total are displayed. The decimal point is for display only
and does not affect K Factors. (The K Factor must be scaled to reflect the DEC LOC,
see Section 7 for calculating the K Factors) Simply press the keypad numbers to move
the decimal point. Only one decimal point can be displayed, multiple decimal points
are not available. Pressing 0 turns off the decimal point.
DEC LOC
As an example, the decimal point will move to the right of the fourth digit from the right
(displays units and thousandths).
Run Mode.
Store new DEC LOC.
The Counter portion of the Batcher is now set up.
ENT
B
B
B
B
D
ENT
4
ENT