beautypg.com

Slide gate requirements, High risk of entrapment area, Non-compliant openings – Controlled Products Systems Group 9100-080 User Manual

Page 6: Compliant openings

background image

9100-065-Z-3-13

4

Slide Gate Requirements

Note: Install
screened wire
mesh to a
non-compliant
gate AND
non-compliant
adjacent fence
that covers
open gate
position
(See above).

X X X

X X X

X X X

X X X

X X

X X X

X X X

72” (6 ft) minimum

6 ft minimum

Non-compliant openings

wider than 2 1/4”.

Less than 2 1/4”

Screened Wire Mesh

Compliant openings

less than 2 1/4”.

Gate Frame and Adjacent Fence Area

Gate Frame and Adjacent Fence Area

The operator is intended for installation only on gates used for vehicles.

Pedestrians must be supplied with a separate

access opening. The pedestrian access opening shall be designed to promote pedestrian usage. Locate the gate such that
persons will not come in contact with the vehicular gate during the entire path of travel of the vehicular gate.
(ref. UL 325 56.8.4.b)

All openings of a horizontal slide gate are
guarded or screened from the bottom of the gate to
a minimum of six (6) feet (1.83 m) above the ground
to prevent a 2 1/4 inch (57.2 mm) diameter sphere
from passing through the openings anywhere in the
gate and in that portion of the adjacent fence that
the gate covers in the open position.
(ref. ASTM F2200-11a, 6.1.2)

Closed Gate

High Risk of Entrapment Area

X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X

X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X

X X X

Adjacent fence that covers open gate position.

Note: A filler post or
barrier may need to be
installed in the gap area
to reduce the distance
to 2 1/4 inches or less.
A contact sensor should
be installed in this area
for safety.
(See
on next
page and page 27).

A gap, measured in the horizontal plane parallel to

the roadway, between a fixed stationary object

nearest the roadway (such as a gate support post)

and the gate frame when the gate is in either the

fully open position or the fully closed position,

shall not exceed 2 1/4 inch (57.2 mm).

(ref. ASTM F2200 6.1.4)

High Risk of Entrapment Area

Gate Support Post

Gate Frame

A

Gates shall be designed, constructed and

installed to not fall over more than 45

degrees from the vertical plane, when a gate

is detatched from the supporting hardware.

Guide

Rollers

Fall Over Bracket

2 1/4” maximum gap area

Illustrations not to scale.