Slide gate requirements, High risk of entrapment area, Non-compliant openings – Controlled Products Systems Group 9100-080 User Manual
Page 6: Compliant openings
9100-065-Z-3-13
4
Slide Gate Requirements
Note: Install
screened wire
mesh to a
non-compliant
gate AND
non-compliant
adjacent fence
that covers
open gate
position
(See above).
X X X
X X X
X X X
X X X
X X
X X X
X X X
72” (6 ft) minimum
6 ft minimum
Non-compliant openings
wider than 2 1/4”.
Less than 2 1/4”
Screened Wire Mesh
Compliant openings
less than 2 1/4”.
Gate Frame and Adjacent Fence Area
Gate Frame and Adjacent Fence Area
The operator is intended for installation only on gates used for vehicles.
Pedestrians must be supplied with a separate
access opening. The pedestrian access opening shall be designed to promote pedestrian usage. Locate the gate such that
persons will not come in contact with the vehicular gate during the entire path of travel of the vehicular gate.
(ref. UL 325 56.8.4.b)
All openings of a horizontal slide gate are
guarded or screened from the bottom of the gate to
a minimum of six (6) feet (1.83 m) above the ground
to prevent a 2 1/4 inch (57.2 mm) diameter sphere
from passing through the openings anywhere in the
gate and in that portion of the adjacent fence that
the gate covers in the open position.
(ref. ASTM F2200-11a, 6.1.2)
Closed Gate
High Risk of Entrapment Area
X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X
X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X
X X X
Adjacent fence that covers open gate position.
Note: A filler post or
barrier may need to be
installed in the gap area
to reduce the distance
to 2 1/4 inches or less.
A contact sensor should
be installed in this area
for safety.
(See
on next
page and page 27).
A gap, measured in the horizontal plane parallel to
the roadway, between a fixed stationary object
nearest the roadway (such as a gate support post)
and the gate frame when the gate is in either the
fully open position or the fully closed position,
shall not exceed 2 1/4 inch (57.2 mm).
(ref. ASTM F2200 6.1.4)
High Risk of Entrapment Area
Gate Support Post
Gate Frame
A
Gates shall be designed, constructed and
installed to not fall over more than 45
degrees from the vertical plane, when a gate
is detatched from the supporting hardware.
Guide
Rollers
Fall Over Bracket
2 1/4” maximum gap area
Illustrations not to scale.