1 main terminal description, Nc no – Controlled Products Systems Group 9100-080 User Manual
Page 32
9100-065-Z-3-13
30
5.1 Main Terminal Description
15
10
6
5
Low Voltage Common
LED Indicator Output
Dry Relay Contact
Gate Tracker - Data
Gate Tracker - Busy
Entrapment Alarm
Alarm Reset
3-Button Close
(DoorKing 3-Button station ONLY)
Exit Loop Logic Output
(DoorKing Loop Detectors ONLY)
3-Button Full Open
(DoorKing 3-Button station ONLY)
Dry Relay Contact
24 VAC - 250 mamp max.
Full Open
Partial Open
Standard Reverse or Stop
Not Used
Low Voltage Common
Full Open
KEY SWITCH
4602
NC
NO
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
•
When gate is closed, this input will fully open
gate.
•
When gate is open and auto close timer SW 1,
switch 2 is turned ON, input will re-set and hold
timer.
•
When gate is open and auto close timer SW 1,
switch 2 is turned OFF, input will close gate.
•
When gate is closing, input will reverse gate.
ON
1
2
345678
SW 1
17
Provides 24 VDC, 250 ma. maximum to power
LED. Operation of LED is dependent on setting of
SW 1, switches 4 and 5 (See page 22).
ON
1 2
3
4 5
6 7 8
SW 1
Operation of relay is dependent on
setting of SW 1, switches 4 and 5.
Relay contacts can be set for Normally
Open (NO) or Normally Closed (NC)
operation.
Contact rating is 1 amp
maximum at 24-volts DC.
ON
12
3
45
678
SW 1
NO
NC
4
•
This input ONLY fuctions when gate is fully
opened or in the closing cycle.
•
When gate is open: auto close timer SW 1,
switch 2 is turned ON, input will re-set and hold
timer.
•
When gate is open: auto close timer SW 1,
switch 2 is turned OFF, input will prevent gate
from closing.
•
When gate is closing: input will stop gate when
SW 2, switch 2 is ON.
•
When gate is closing: input will reverse gate
when SW 2, switch 2 is OFF.
ON
1
2
345678
SW 2
ON
1
2
345678
SW 1
Jumper Wire SW 2, switch 2 OFF (Dual Operators only)
Jumper Wire SW 2, switch 2 OFF (Exit Loop Partial Open)
SECTION 5 - WIRING
For long gate application. SW 2, switch 3
must be OFF. Same operation as #4
terminal above but will only open a closed
gate 14-Ft. or reverse a closing gate to the
14-Ft. open position.
ON
12
3
45678
SW 2
ON
1
2
345678
SW 2
-
Terminal #10 connected to terminal #5 will PARTIALLY open
plug-in exit loop detector (Single channel) for a single operator.
-
Terminal #10 connected to terminal #4 will FULLY open
bi-parting gates. Dual operators ONLY using DoorKing’s
plug-in DUAL channel loop detector. (Page 33).
•
lf SW 2, switch 1 is ON, the plug-in exit loop detector
(Single channel) will FULLY open the gate (Normal Setting).
Single operator use ONLY.
•
lf SW 2, switch 1 is OFF, the normal exit loop port
function is bypassed and a jumper wire is needed to open
and close gate(s) for certain applications: