30

5.1 Main Terminal Description

15

10

6

5

Low Voltage Common

LED Indicator Output

Dry Relay Contact

Gate Tracker - Data

Gate Tracker - Busy

Entrapment Alarm

Alarm Reset

3-Button Close

(DoorKing 3-Button station ONLY)

Exit Loop Logic Output

(DoorKing Loop Detectors ONLY)

3-Button Full Open

(DoorKing 3-Button station ONLY)

Dry Relay Contact

24 VAC - 250 mamp max.

Full Open

Partial Open

Standard Reverse or Stop

Not Used

Low Voltage Common

Full Open

KEY SWITCH

4602

NC

NO

18

17

16

15

14

13

12

11

10

9

8

7

6

5

4

3

2

1

When gate is closed, this input will fully open

gate.

When gate is open and auto close timer SW 1,

switch 2 is turned ON, input will re-set and hold
timer.

When gate is open and auto close timer SW 1,

switch 2 is turned OFF, input will close gate.

When gate is closing, input will reverse gate.

ON

1

2

345678

SW 1

17

Provides 24 VDC, 250 ma. maximum to power
LED. Operation of LED is dependent on setting of
SW 1, switches 4 and 5 (See page 22).

ON

1 2

3

4 5

6 7 8

SW 1

Operation of relay is dependent on
setting of SW 1, switches 4 and 5.
Relay contacts can be set for Normally
Open (NO) or Normally Closed (NC)
operation.

Contact rating is 1 amp
maximum at 24-volts DC.

ON

12

3

45

678

SW 1

NO

NC

4

This input ONLY fuctions when gate is fully

opened or in the closing cycle.

When gate is open: auto close timer SW 1,

switch 2 is turned ON, input will re-set and hold
timer.

When gate is open: auto close timer SW 1,

switch 2 is turned OFF, input will prevent gate
from closing.

When gate is closing: input will stop gate when

SW 2, switch 2 is ON.

When gate is closing: input will reverse gate

when SW 2, switch 2 is OFF.

ON

1

2

345678

SW 2

ON

1

2

345678

SW 1

Jumper Wire SW 2, switch 2 OFF (Dual Operators only)

Jumper Wire SW 2, switch 2 OFF (Exit Loop Partial Open)

SECTION 5 - WIRING

For long gate application. SW 2, switch 3
must be OFF. Same operation as #4
terminal above but will only open a closed
gate 14-Ft. or reverse a closing gate to the
14-Ft. open position.

ON

12

3

45678

SW 2

ON

1

2
345678

SW 2

-

Terminal #10 connected to terminal #5 will PARTIALLY open

plug-in exit loop detector (Single channel) for a single operator.

-

Terminal #10 connected to terminal #4 will FULLY open

bi-parting gates. Dual operators ONLY using DoorKing’s
plug-in DUAL channel loop detector.
(Page 33).

lf SW 2, switch 1 is ON, the plug-in exit loop detector

(Single channel) will FULLY open the gate (Normal Setting).
Single operator use ONLY.

lf SW 2, switch 1 is OFF, the normal exit loop port

function is bypassed and a jumper wire is needed to open
and close gate(s) for certain applications: