beautypg.com

This gate operator must be properly grounded, 115 vac, Wire size / max distance in feet – Controlled Products Systems Group 9100-080 User Manual

Page 22: Dual operators, Do not, External power disconnect switch, Never, Danger

background image

9100-065-Z-3-13

20

REV

ERS

E

SENS

ITIVIT

Y

REVER

SE

LO

OP

EXI

T

LOOP

KEY

SW

ITC

H

DOOR

KIN

G

460

2-0

10

SW1

SW2

OP

EN

TIM

ER

170

275

460

685

85

135

230

340

2.1 High Voltage Wire Runs

2.2 High Voltage Terminal Connection

Use the wire restrainers inside
operator to keep wire away
from moving parts.

Wire Size / Max Distance in Feet

12 AWG

10 AWG

8 AWG

6 AWG

Single 9100: 5.4 Amp Motor

Dual 9100’s, Single Power Source

SECTION 2 - AC POWER TO OPERATOR(S)

Before attempting to connect any wiring to the operator, be sure that the circuit breaker in the electrical panel is in the OFF
position. Permanent wiring must be installed to the operator as required by local electrical codes. It is recommended that a
licensed electrical contractor perform this work.
Since building codes vary from city to city, we highly recommend that you check with your local building department prior
to installing any permanent wiring to be sure that all wiring to the operator (both high and low voltage) complies with local
code requirements.

THIS GATE OPERATOR MUST BE PROPERLY GROUNDED!!

Route incoming AC power wire through the high voltage conduit and run wire in the operator as shown.

Be sure wiring is installed in accordance with local

codes. Be sure to color code all wiring.

It is recommended that a surge suppressor be installed

on the high voltage power lines to help protect the
operator and circuit board from surges and power
fluctuations.

Dual operators (Primary/Secondary) require AC power to EACH operator.

AC Power

AC Power

Dual Operators

Loosen the 2 nuts

under the electronic box

to swing box up.

“Optional” 3.3 Amp Heater Installation Note: When installing the heater(s), refer to the “high voltage AC power wire size and
distance requirements”
table on the instruction sheet with the heater kit (P/N 1601-154) for AC power wire run requirements.

If power wiring is greater than the maximum distance shown, it is
recommended that a service feeder be installed. When large gauge wire
is used, a separate junction box must be installed for the operator
connection. The wire table is based on stranded copper wire. Wire run
calculations are based on a power source
with a 3% voltage drop on the power line,
plus an additional 10% reduction in distance
to allow for other losses in the system.

Never

run low voltage rated wire insulation in the

same conduit as high voltage rated wire insulation.

Chassis

Ground

DANGER

HIGH VOLTAGE

115 VAC Connection

High Voltage
Conduit

MOV

- Helps

protect operator

from power surges.

DO NOT

power up and cycle the

operator until the “Physical stops”
have been installed.
Damage could occur to
the gate and
operator.

A separate power disconnect

switch may be needed in your

area. Check local building

codes before installation.

115 VAC

AC Power Terminal

White - Neutral
Black - 115 VAC Hot
Green - Chassis
Ground

Hot

Neu

High Voltage

AC Power Wire

External Power

Disconnect Switch

AC POWER

ON

OFF

Every time the operator is powered up, the First open command will automatically run “Multiple
gate cycles”
that will locate and remember the gate’s open and close positions (See page 24).