2.1 High Voltage Wire Runs
2.2 High Voltage Terminal Connection
Use the wire restrainers inside
operator to keep wire away
from moving parts.
Wire Size / Max Distance in Feet
12 AWG
10 AWG
8 AWG
6 AWG
Single 9100: 5.4 Amp Motor
Dual 9100’s, Single Power Source
SECTION 2 - AC POWER TO OPERATOR(S)
Before attempting to connect any wiring to the operator, be sure that the circuit breaker in the electrical panel is in the OFF
position. Permanent wiring must be installed to the operator as required by local electrical codes. It is recommended that a
licensed electrical contractor perform this work.
Since building codes vary from city to city, we highly recommend that you check with your local building department prior
to installing any permanent wiring to be sure that all wiring to the operator (both high and low voltage) complies with local
code requirements.
THIS GATE OPERATOR MUST BE PROPERLY GROUNDED!!
•
Route incoming AC power wire through the high voltage conduit and run wire in the operator as shown.
•
Be sure wiring is installed in accordance with local
codes. Be sure to color code all wiring.
•
It is recommended that a surge suppressor be installed
on the high voltage power lines to help protect the
operator and circuit board from surges and power
fluctuations.
•
Dual operators (Primary/Secondary) require AC power to EACH operator.
AC Power
AC Power
Dual Operators
Loosen the 2 nuts
under the electronic box
to swing box up.
“Optional” 3.3 Amp Heater Installation Note: When installing the heater(s), refer to the “high voltage AC power wire size and
distance requirements” table on the instruction sheet with the heater kit (P/N 1601-154) for AC power wire run requirements.
If power wiring is greater than the maximum distance shown, it is
recommended that a service feeder be installed. When large gauge wire
is used, a separate junction box must be installed for the operator
connection. The wire table is based on stranded copper wire. Wire run
calculations are based on a power source
with a 3% voltage drop on the power line,
plus an additional 10% reduction in distance
to allow for other losses in the system.
Never
run low voltage rated wire insulation in the
same conduit as high voltage rated wire insulation.
Chassis
Ground
DANGER
HIGH VOLTAGE
115 VAC Connection
High Voltage
Conduit
MOV
- Helps
protect operator
from power surges.
DO NOT
power up and cycle the
operator until the “Physical stops”
have been installed.
Damage could occur to
the gate and
operator.
A separate power disconnect
switch may be needed in your
area. Check local building
codes before installation.
115 VAC
AC Power Terminal
White - Neutral
Black - 115 VAC Hot
Green - Chassis
Ground
Hot
Neu
High Voltage
AC Power Wire
External Power
Disconnect Switch
AC POWER
ON
OFF
Every time the operator is powered up, the First open command will automatically run “Multiple