beautypg.com

2 secondary entrapment protection device locations – Controlled Products Systems Group 9100-080 User Manual

Page 29

background image

9100-065-Z-3-13

27

ON

EXIT
LOOP

4602

SW1

NC

NO

18

17

16

15

14

13

12

11

10

9

8

7

6

5

4

3

2

1

1
2
3
4
5

Gate Frame

Gate Frame

Non-Secure Side

Outside Property

Secure Side

Inside Property

Filler Post or Barrier

Reversing Edge (Open Contact Sensor)

4.2 Secondary Entrapment Protection Device Locations

Typical UL Photo Sensor mounting height
and distance away from gate.

If the distance between the gate
and wall is greater than 2 1/4”.

Wall

UL sensor mounted on post.

UL sensor mounted on wall.

A filler post or barrier may need to be installed between the
gate and wall area to reduce the distance to 2 1/4” or less.
A reversing edge should be installed on the post or barrier
for safety (See page 4 for more information).

Photo Sensors (With Filler Post and Reverse Edge) Sample Setup

Closed Gate

Wall

Normally Open

Normally Open

Normally Open

Common

Common

Normally Open

Photo Sensor Power Note: Photo sensors can be powered by the built-in
convenience outlets located on the operator (See previous page).

Closing-direction photo sensors wired to UL 325 terminal.

Closing-Direction Photo Beam

Opening-Direction Photo Beam

5-Pin UL 325 Terminal Wiring

“Reverse” Closing-Direction Option

Filler Post with Opening-Direction Reversing Edge (If necessary, see above)

OPEN Entrapment Sensor

CLOSE Entrapment Sensor

OPEN Contact Sensor

CLOSE Contact Sensor

Low Voltage Common

IF the closing-direction photo sensor is wired to the UL 325 terminal, a
closing-direction photo beam that gets obstructed will STOP the gate, then
resume closing the gate when the obstructed photo beam has been cleared.

IF the closing-direction
photo sensor is wired
to the #6 main terminal,
a closing-direction
photo beam that gets
obstructed will
REVERSE the gate back
to the open position.
See pages 30 and 31
for more information.

1
2
3

4

5

ON

1

2

345678

SW 2

SW 2, switch 2

must be OFF.

Main Terminal

Photo sensors may be installed on either side of gate frame, as close as
practical to the gate but no further away than 5”.

No higher than

27.5” above grade.

21” is typical for

most installations.

Note: Additional
photo sensors can
be added above
the 27.5” height.

5”

or

Less

5”

or

Less