3.1 4602 Circuit Board Description and Adjustments

SECTION 3 - ADJUSTMENTS

The switch settings and adjustments in this chapter should be made after your installation and wiring to the operator(s) is
complete. Whenever any of the programming switches on the circuit board are changed, power must be shut-off, and then
turned back on for the new setting to take effect. Every time
the 9100 is powered up, the First open command will automati-
cally run “Multiple gate cycles” that will locate and remember the gate’s open and close positions (See page 24).

Auto-close timer (when
turned on) SW 1, switch 2.


Adjust from 1 second
(full counter clockwise) to
approximately 23 seconds
(full clockwise).

Dry relay contacts
(terminals 15-16) can be
set for Normally Open
(NO) or Normally Closed
(NC) operation by placing
the relay shorting bar on the
N.O. or N.C. pins respectively.
SW 1, switches 4 and 5 must
be set to control relay. See
next page for descriptions.

1 23

Auto-Close Timer

Dual Channel Loop Detector

Single Channel Loop Detector

Dry Relay Contact

NC

NO

Set the DIP-switches
on the circuit board
to the desired
setting. See switch
setting charts on
next 2 pages.

DIP-Switches

ON

1
2
345678

SW 2

ON

1
2
345678

SW 1

ON

1

2

345678

SW 1

Cycles the operator
when pressed. Gate
opens to full open
position ONLY.

Surface Mounted LEDs

Indicates that low voltage power is applied to the circuit board.

Input LEDs should be OFF and will only illuminate when the input is activated. Pulse LEDs will
blink as the operator is running. They can be either ON or OFF when the operator is stopped.

Key Switch

Adjust reversing sensitivity.
Full counter clockwise for
minimum sensitivity, full
clockwise for maximum
sensitivity. See page 25.

Min Max

Sensitivity

Inherent Reverse Sensor

Self-test (when
turned on) SW 1,
switch 6.

CAUTION

Do not run self-test with the operator
connected to the gate. The drive chain
must be disconnected before running
the self-test. This feature is designed
for bench testing ONLY.

Self-Test

ON

1
2
345

6

78

SW 1

UL 325

Terminal

Power LED

Pulse LEDs

Input LEDs

Magnetic

Sensors

See page 25.

ON

1 2

3

4 5

6 7 8

SW 1

Typical Settings

Exit Loop Port

Reverse Loop Port

See page 29.

See page 33.