Electrical installation/ high voltage wiring – Controlled Products Systems Group 1601-080 User Manual
Page 9
1601-065-M-05-07
10 installation
guide
",!#+
7()4%
",!#+
",!#+
",!#+
7()4%
'2%%.
electrical installation/high voltage wiring
MODEL
VOLTS
AMPS
WIRE SIZE / DISTANCE IN FEET
12 AWG
10 AWG
8 AWG
6 AWG
1601/1603
120
5.4
170
275
460
685
1601/1603
230
2.7
685
1100
1830
2750
1601/1603
460
1.35
2875
4600
7665
11500
The distance shown in the chart is measured in feet from the operator to the power source.
If power wiring is greater than the maximum distance shown, it is recommended that a
service feeder be installed. When large gauge wire is used, a separate junction box must
be installed for the operator connection. The wire table is based on stranded copper wire.
Wire run calculations are based on a 3% voltage drop on the power line, plus an additional
10% reduction in distance to allow for other losses in the system.
Connect the High-Voltage wiring to the
terminal block as shown.
2
All wiring must comply with local code requirements.
To protect against surges and power fl uctuations it is recommended that a surge suppresser be installed on
the high voltage power lines
For 230 and 460 Volt 3-phase input power, use only two legs of the incoming 3-phase power.
From the High-Voltage conduit, route the
wiring cable up to the terminal block.
1
1
2