20 installation
guide
electrical installation/timer down application
1 2 3 4 5 6 7 8 9
10 11 12 13 14
SW2
7
8
3- DATA OUT
2- DATA IN
1- COMMON
TB 2
TB 1
DOWN
PORT
9409
Loop
Detector
!CCESS
#ONTROL
$EVICE
COM
N.O.
!RMING
/PTIONAL
2EVERSE
2EVERSE
1
2
3
4
5
6
7
8
ON
OFF
SW1
3PEED
Spacing of the loops is critical when using this configuration. Be sure that the loops are spaced as shown in the diagram.
1
2
3
4
5
Use a 9405 loop detector plugged into the DOWN port on the 1601 circuit board. Connect the REVERSE loops, wired in series, to
terminals TB-1 and the ARMING loop to terminals TB-2.
If the optional arming loop is not used, use a 9406 detector plugged into the DOWN port on the 1601 circuit board and connect
the REVERSE loops, wired in series, to terminals TB-1 on this detector.
The timer (SW-1, switch 7) should be ON. The arm will rotate down after the vehicle clears the reverse loops and the timer
times out.
SW-1, switch 4 must be OFF.
1
2
3
4
5