SPECIFICATIONS
Supply voltage
230 V / 50 Hz
Protection index
wall version: IP 65
mobile version: IP44
Dosage rate
0,01 % à 99,9 %
Sensor resolution
< 250 impulses per litre
Output signal
impulses for the consumption of water and active product
Flow impulses
transistor output, max. 30 V, 100 mA
Water pressure
see the versions table
Authorised flow
see the versions table
Display
LCD 15 x 60 mm
Internal counters
daily and totaliser for water and active product
Approval/Certificate
all the elements conform to the CE
Weight of wall system
approx. 6.95 kg
Weight of mobile system
approx. 18.2 kg, empty
5 MAINTENANCE AND TROUBLESHOOTING
Regularly check:
The integrity of electrical supply cables and all electrical connections.
The integrity of the appliance housing (no dent or deterioration of any kind that
could affect the watertightness).
The tightness of sealing parts (cable seals, covers, etc.).
5.1 Maintenance
After dosing with viscuous or crystallised liquids, rinse the pump with clean water.
After rinsing leave water in the pump head.
If necessary, remove the dosing pump anti-return valves manually to clean them (see the type
7800 dosing pump user manual).
• Replace the anti-return valves carefully.
• Fit the parts in the correct order.