16 - konti-Dos

english

3.2 Modifying the control unit's Qmax and DRmax parameters

The maximum flow Qmax, depends on the version of the konti-Dos system (see paragraph 2.3).

The maximum dosage rate DRmax is defined as follows:

DR

max.

= Q

max. pump

[l/h] / Q

max.

[l/h]

When one of the Qmax or DRmax values is modified, re-calculate the second value using the
above equation and modify this value in the programming menu.

3.3 Examples of DRmax and Qmax calculations

Example 1

Qmax = 240 l/h
Qpump = 12 l/h

DR

max.

= Q

max. pump

[l/h] / Q

max.

[l/h]

= 12 l/h / 240 l/h = 0,05, e.g. 5 %

Example 2

DRmax = 10%
Qpump = 48 l/h

Q

max.

[l/h]

= Q

max. pump

[l/h] / DR

max.

= 48 l/h / 0,1 = 480 l/h

ATTENTION

To obtain correct dosages, these modifications should only be made
by qualified personnel.