0x2f11, Controller, 0x2f12 – Burkert Type 8746 User Manual
Page 25: Sys param _1, 0x2f13, Sys param _2, Ensor, Ktor, Odul description of initiation files eds, 0x2f11 controller
S
ensor
A
ktor
M
odul
Description of initiation files EDS
Description_of_InitiationFilesEDS_2
Version 1.4
page 23 / 27
0x2F11
Controller
sub name
description
ac
ce
ss
type
flags
accessrights
im
p
o
rt
Im
p
o
rt
d
e
vID
S
IM
-C
a
rd
R
-
u
se
r
W
-
u
se
r
R
-
a
d
v.
u
s
e
r
W
-
a
d
v.
u
se
r
R
-
in
sta
ll
e
r
W
-
ins
ta
lle
r
R
-
b
u
e
rke
rt
W
-
b
u
e
rke
rt
1 kp
Controller parameter
RW
x
x - - x x x x x x
2 tn
Controller parameter
RW
x
x - - x x x x x x
3 SP Source
Defines which source is used as setpoint.
See attachement: “
RW
x
x
x x x x x x x x
4 Stored SP Percent
Value in % of QNom.
It can be used as setpoint source (maybe in a stand alone
system).
see sub3
RW
x
x
x x x x x x x x
5 Threshold Percent
Defines the controllers threshold in percent as REAL32
(0..30%).
Deactivated (0%) as default.
The threshold of the controller decide, below which value
(as percent of QNominal) the actuating variable is set to
zero directly (y2 = 0). The used setpoint is manipulated by
max positive (negative) rise time before.
RW
x
x
x - x x x x x x
6
Max Positive Rise Time
Sec
Specifies the maximal positive rise time of an setpoint jump
from 0% to 100% in seconds. This rise time is used for
every positive setpoint jump.
By a value of 0, the setpoint
isn’t manipulated by this functionality.
RW
x
x
x - x x x x x x
7
Max Negative Rise
Time Sec
Specifies the maximal negative rise time of an setpoint jump
from 0% to -100% in seconds. This rise time is used for
every negative setpoint jump.
By a value of 0, the setpoint
isn’t manipulated by this functionality.
RW
x
x
x - x x x x x x
8 Control In xFilter
filter for the actual flow which is used for the closed loop
controller as input value
new since EDS 1.4 cutoff frequency fg in Hz as FLOAT32
(default deactivated 0 Hz)
RW
x
x
x - x - x x x x
0x2F12
Sys Param _1
0x2F13
Sys Param _2
The customers fluid system in conjunction with the mounted valve is described by the Sys Param _x for each gas
calibration. It will be detected during the devices autotune function to manipulate the controller parameters in several
working ranges to get the best behaviour.
sub name
description
ac
ce
ss
type
flags
accessrights
im
p
o
rt
Im
p
o
rt
d
e
vID
S
IM
-C
a
rd
R
-
u
se
r
W
-
u
se
r
R
-
a
d
v.
u
s
e
r
W
-
a
d
v.
u
se
r
R
-
in
sta
ll
e
r
W
-
ins
ta
lle
r
R
-
b
u
e
rke
rt
W
-
b
u
e
rke
rt
1 Dutycycle1
value duty cycle for 0% flow
RW
- - - - x x x x
2 Dutycycle2
value duty cycle for 25% flow
RW
- - - - x x x x
3 Dutycycle3
value duty cycle for 50% flow
RW
- - - - x x x x
4 Dutycycle4
value duty cycle for 75% flow
RW
- - - - x x x x
5 Dutycycle5
value duty cycle for 100% flow
RW
- - - - x x x x