beautypg.com

0x2d00, Common, 0x2d01 – Burkert Type 8746 User Manual

Page 19: Diagnose, Ensor, Ktor, Odul description of initiation files eds, 0x2d00 common, 0x2d01 diagnose

background image

S

ensor

A

ktor

M

odul

Description of initiation files EDS

Description_of_InitiationFilesEDS_2

Version 1.4

page 17 / 27

0x2D00

Common

sub name

description

ac

ce

ss

type

flags

accessrights

im

p

o

rt

Im

p

o

rt

d

e

vID

S

IM

-C

a

rd

R

-

u

se

r

W

-

u

se

r

R

-

a

d

v.

u

s

e

r

W

-

a

d

v.

u

se

r

R

-

in

sta

ll

e

r

W

-

ins

ta

lle

r

R

-

b

u

e

rke

rt

W

-

b

u

e

rke

rt

1 Device Type

Buerkert specific device types e.g.

8741, 8742…

Value will be adopted to Product Code of Buerkert Device
Description Object during device start.

RO

x - x - x - x x

2 Ident Number

Buerkert specific devices ID No.
Value will be adopted to Ident Number of Buerkert Device
Description Object during device start.

RO

x - x - x - x x

3 Serial Number

Buerkert specific devices SN.
Value will be adopted to Serial Number of Buerkert Device
Description Object during device start.

RO

x - x - x - x x

4 Manufacture Date

Buerkert date of manufacturing
Value will be adopted to Manufacture Date of Buerkert
Device Description Object during device start.

RO

x - x - x - x x

5 Sample Time Ms

Controllers sample time in ms

RO

- - x - x - x x

6 Autotune Active

It’s used for starting a device autotune. During autotune the
system is analysed and new controller paramters are
identified.
1: start autotune
after autotune normal mode will be reactivated
(value is resetted automatically)
0: normal mode (autotune inactive)

RW

x - x x x x x x

7 Control Device

Specifies the general device class
0: Measuring device
1: Control device

RO

x - x - x - x x

0x2D01

Diagnose

sub name

description

ac

ce

ss

type

flags

accesrigths

im

p

o

rt

Im

p

o

rt

d

e

vID

S

IM

-C

a

rd

R

-

u

se

r

W

-

u

se

r

R

-

a

d

v.

u

s

e

r

W

-

a

d

v.

u

se

r

R

-

in

sta

ll

e

r

W

-

ins

ta

lle

r

R

-

b

u

e

rke

rt

W

-

b

u

e

rke

rt

1

Medium Temperature
Measure Time sec

Cycle time for medium temperature measurement

RW

x

x

x - x - x x x x

B

Device Temperature
Limit Low

A device warning will be generated if device temperature
falls below this value in degree celsius as float32 value

RO

- - - - x - x x

C

Device Temperature
Limit High

A device warning will be generated if device temperature
passes this value in degree celsius as float32 value

RO

- - - - x - x x

This manual is related to the following products: